Equipment and appliances supported from the ground shall be level and firmly supported on a concrete slab or other approved material extending not less than 3 inches (76 mm) above the adjoining ground. Such support shall be in accordance with the manufacturer's installation instructions. Appliances suspended from the floor shall have a clearance of not less than 6 inches (152 mm) from the ground.

Related Code Sections

(B) Communications Systems, Clearance From Ground
Electrical Safety Code, Table 232-1, which provides for clearances of wires, conductors, and cables above ground and roadways, rather than using ...
(A) Special Occupancies, Vertical Clearances
Conductors shall have a vertical clearance to ground in accordance with 225.18. These clearances shall apply only to wiring installed outside ...
(D) Equipment for General Use, Clearances
Clearances from resistors and reactors to grounded surfaces shall be adequate for the voltage involved ...
609.4 Specific Appliances, Clearance
(51 mm). Where such clearances cannot be provided, the ground below and to the sides shall be excavated to form a pit under the furnace so ...