Required handrails shall be of one of the following types or provide equivalent graspability.
  1. Type I. Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches (32 mm) and not greater than 2 inches (51 mm). If the handrail is not circular, it shall have a perimeter of not less than 4 inches (102 mm) and not greater than 61/4 inches (160 mm) and a cross section of not more than 21/4 inches (57 mm). Edges shall have a radius of not less than 0.01 inch (0.25 mm).
  2. Type II. Handrails with a perimeter greater than 61/4 inches (160 mm) shall have a graspable finger recess area on both sides of the profile. The finger recess shall begin within 3/4 inch (19 mm) measured vertically from the tallest portion of the profile and have a depth of not less than 5/16 inch (8 mm) within 7/8 inch (22 mm) below the widest portion of the profile. This required depth shall continue for not less than 3/8 inch (10 mm) to a level that is not less than 13/4 inches (45 mm) below the tallest portion of the profile. The width of the handrail above the recess shall be not less than 11/4 inches (32 mm) and not more than 23/4 inches (70 mm). Edges shall have a radius of not less than 0.01 inch (0.25 mm).

Related Code Sections

R311.7.8.5 Building Planning, Grip Size
Required handrails shall be of one of the following types or provide equivalent graspability. Type I. Handrails with a circular cross section shall ...
505.6 General Site and Building Elements, Gripping Surface
Gripping surfaces shall be continuous, without interruption by newel posts, other construction elements, or obstructions. EXCEPTIONS: 1 ...
505.6 General Site and Building Elements, Gripping Surface
Gripping surfaces shall be continuous, without interruption by newel posts, other construction elements, or obstructions. Exceptions: Handrail ...