1504.8 Gray Water System Color and Marking Information
JUMP TO FULL CODE CHAPTER
Pressurized gray water distribution systems shall be identified as containing nonpotable water in accordance with Section 601.3 of this code.
Related Code Sections
1504.8 Alternate Water Sources for Nonpotable Applications, Gray Water System Color and Marking Information
Pressurized gray water distribution systems shall be identified as containing nonpotable water in accordance with Section 601.3 of this code ...
2018 Uniform Plumbing Code of Nevada > 15 Alternate Water Sources for Nonpotable Applications > 1504.0 Subsurface Irrigation System Zones > 1504.8 Gray Water System Color and Marking Information
P2901.2.2.1 Water Supply and Distribution, Color
reclaimed, rain and gray-water distribution systems ...
Residential Code 2018 of Nevada > 29 Water Supply and Distribution > P2901 General > P2901.2 Identification of Nonpotable Water Systems > P2901.2.2 Distribution Pipe Labeling and Marking > P2901.2.2.1 Color
601.3 Water Supply and Distribution, Identification of a Potable and Nonpotable Water System
or factory marked as follows: Gray water systems shall be marked in accordance with this section with the words "CAUTION: NON POTABLE GRAY WATER, DO ...
2018 Uniform Plumbing Code of Nevada > 6 Water Supply and Distribution > 601.0 General > 601.3 Identification of a Potable and Nonpotable Water System
P3009.13.4 Sanitary Drainage, Coloring
The gray water shall be dyed blue or green with a food-grade vegetable dye before such water is supplied to the fixtures ...
Residential Code 2012 of Nevada > 30 Sanitary Drainage > P3009 Gray Water Recycling Systems > P3009.13 Flushing Water Systems > P3009.13.4 Coloring
322.120 Wiring Methods and Materials, Marking
be identified throughout its length by means of a distinctive and durable white or gray marking. Informational Note: The color gray may have been used ...
National Electrical Code 2017 of Nevada > 3 Wiring Methods and Materials > 322 Flat Cable Assemblies: Type FC > 322.120 Marking