// CODE SNIPPET
312.6 Gravity Sewer Test
JUMP TO FULL CODE CHAPTER
Gravity sewer tests shall consist of plugging the end of the building sewer at the point of connection with the public sewer, filling the building sewer with water, testing with not less than a 5-foot (1524 mm) head of water and maintaining such pressure for 15 minutes.
Related Code Sections
312.6 General Regulations, Gravity Sewer Test
Gravity sewer tests shall consist of plugging the end of the building sewer at the point of connection with the public sewer , filling ...
2014 FBC - Plumbing, 5th edition > 3 General Regulations > 312 Tests and Inspections > 312.6 Gravity Sewer Test
312.6 General Regulations, Gravity Sewer Test
Gravity sewer tests shall consist of plugging the end of the building sewer at the point of connection with the public sewer , filling ...
2017 FBC - Plumbing, 6th edition > 3 General Regulations > 312 Tests and Inspections > 312.6 Gravity Sewer Test
312.6 General Regulations, Gravity Sewer Test
Gravity sewer tests shall consist of plugging the end of the building sewer at the point of connection with the public sewer, filling ...
2020 FBC - Plumbing, 7th edition > 3 General Regulations > 312 Tests and Inspections > 312.6 Gravity Sewer Test
Section 717 Sanitary Drainage, Replacement of Underground Sewers by Pipe-Bursting Methods
The replacement of building sewer piping by pipe-bursting methods shall be limited to gravity ...
2017 FBC - Plumbing, 6th edition > 7 Sanitary Drainage > 717 Replacement of Underground Sewers by Pipe-Bursting Methods
Section P3010 Sanitary Drainage, Replacement of Undergroundbuilding Sewers and Building Drains by Pipe Bursting Methods
This section shall govern the replacement of existing building sewer and building drain piping by pipe-bursting methods ...
2020 FBC - Residential, 7th edition > 30 Sanitary Drainage > P3010 Replacement of Undergroundbuilding Sewers and Building Drains by Pipe Bursting Methods