L 402.2.1 Gravity, Pressure Assisted, and Electro-Hydraulic Tank Type Water Closets
Go To Full Code Chapter
Gravity, pressure assisted, and electro-hydraulic tank-type water closets shall have a maximum effective flush volume of not more than 1.28 gallons (4.8 Lpf) of water per flush in accordance with ASME A112.19.2/CSA B45.1 or ASME A112.19.14 and shall be listed to the EPA WaterSense Specification for Tank-Type Toilets. The effective flush volume for dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush.
Related Code Sections
L 402.2.1 Sustainable Practices, Gravity, Pressure Assisted, and Electro-Hydraulic Tank Type Water Closets
Gravity, pressure assisted, and electro-hydraulic tank-type water closets shall have a maximum effective flush volume of not more than 1.28 gallons ...
P2712.9 Plumbing Fixtures, Electro-Hydraulic Water Closets
Electro-hydraulic water closets shall conform to ASME A112.19.2/CSA B45.1 ...
24.2.5 Water Supplies, Gravity Tanks
An elevated tank installed in accordance with NFPA 22 shall be an acceptable water supply source ...
26.7.2 Marine Systems, Pressure Tank
in accordance with 24.2.4. A glass gauge shall be provided to indicate the correct level of water within the pressure tank. Arrangements shall ...
23.3.5 Plans and Calculations, Hydraulic Reports
Hydraulic calculations shall be prepared on form sheets that include a summary sheet, a graph sheet, a water supply analysis, a node analysis ...