409.3 Graspability
JUMP TO FULL CODE CHAPTER
Handrails with a circular cross section shall have an outside diameter of at least 1.25 inches (32 mm) and not greater than 2 inches (51 mm) or shall provide equivalent graspability. If the handrail is not circular, it shall have a perimeter dimension of at least 4 inches (102 mm) and not greater than 6.25 inches (159 mm) with a maximum cross-section dimension of 2.25 inches (57 mm). Edges shall have a minimum radius of 0.01 inch (3.2 mm).
Related Code Sections
409.3 Egress, Graspability
provide equivalent graspability. If the handrail is not circular, it shall have a perimeter dimension of at least 4 inches (102 mm) and not greater ...
409.3 Egress, Graspability
provide equivalent graspability. If the handrail is not circular, it shall have a perimeter dimension of at least 4 inches (102 mm) and not greater ...
1012.3 Means of Egress, Handrail Graspability
All required handrails shall comply with Section 1012.3.1.or shall provide equivalent graspability. Exception: In Group R-3 occupancies ...
1012.3 Means of Egress, Handrail Graspability
All required handrails shall comply with Section 1012.3.1 or shall provide equivalent graspability. Exception: In Group R-3 occupancies ...
1014.3 Means of Egress, Handrail Graspability
Required handrails shall comply with Section 1014.3.1 or shall provide equivalent graspability. Exception: In Group R-3 occupancies; within ...