R402.3.3 Glazed Fenestration Exemption
JUMP TO FULL CODE CHAPTER
Not greater than 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be exempt from the U-factor and SHGC requirements in Section R402.1.2. This exemption shall not apply to the U-factor alternative in Section R402.1.4 and the Total UA alternative in Section R402.1.5.
Related Code Sections
R402.3.3 [RE] Residential Energy Efficiency, Glazed Fenestration Exemption
Not greater than 15 square feet (1.4 m 2 ) of glazed fenestration per dwelling unit shall be exempt from the U -factor and SHGC requirements ...
2018 Philadelphia Energy Conservation Code > 4 [RE] Residential Energy Efficiency > R402 Building Thermal Envelope > R402.3 Fenestration (Prescriptive) > R402.3.3 Glazed Fenestration Exemption
N1102.3.3 [RE] Energy Efficiency, (R402.3.3) Glazed Fenestration Exemption
Up to 15 square feet (1.4 m 2 ) of glazed fenestration per dwelling unit shall be permitted to be exempt from U -factor and SHGC requirements ...
2018 Philadelphia Residential Code > 11 [RE] Energy Efficiency > N1102 (R402) Building Thermal Envelope > N1102.3 (R402.3) Fenestration (Prescriptive) > N1102.3.3 (R402.3.3) Glazed Fenestration Exemption
C402.4 [CE] Commercial Energy Efficiency, Fenestration (Prescriptive)
of solar gain into the space in multiple steps. Dynamic glazing shall be considered separately from other fenestration, and area-weighted averaging ...
2018 Philadelphia Energy Conservation Code > 4 [CE] Commercial Energy Efficiency > C402 Building Envelope Requirements > C402.4 Fenestration (Prescriptive)
R503.1.1.1 [RE] Existing Buildings, Replacement Fenestration
Where some or all of an existing fenestration unit is replaced with a new fenestration product, including sash and glazing, the replacement ...
2018 Philadelphia Energy Conservation Code > 5 [RE] Existing Buildings > R503 Alterations > R503.1 General > R503.1.1 Building Envelope > R503.1.1.1 Replacement Fenestration
R303.1.3 [RE] General Requirements, Fenestration Product Rating
- factor from Table R303.1.3(1) or R303.1.3(2). The solar heat gain coefficient (SHGC) and visible transmittance (VT) of glazed fenestration ...
2018 Philadelphia Energy Conservation Code > 3 [RE] General Requirements > R303 Materials, Systems and Equipment > R303.1 Identification > R303.1.3 Fenestration Product Rating