Section 2409 Glass in Elevator Hoistway

Go To Full Code Chapter
2409.1 Glass in Elevator Enclosures
Glass in elevator enclosures shall be laminated glass conforming to ANSI Z97.1 or 16 CFR Part 1201. Markings as specified in the applicable standard shall be on each separate piece of glass and shall remain visible after installation.