1910.331(c)(1) Generation, Transmission, and Distribution Installations
JUMP TO FULL CODE CHAPTER
Installations for the generation, control, transformation, transmission, and distribution of electric energy (including communication and metering) located in buildings used for such purposes or located outdoors.
Note 1 to paragraph (c)(1): Work on or directly associated with installations of utilization equipment used for purposes other than generating, transmitting, or distributing electric energy (such as installations which are in office buildings, warehouses, garages, machine shops, or recreational buildings, or other utilization installations which are not an integral part of a generating installation, substation, or control center) is covered under paragraph (a)(1) of this section.
Note 2 to paragraph (c)(1): For work on or directly associated with utilization installations, an employer who complies with the work practices of §1910.269 (electric power generation, transmission, and distribution) will be deemed to be in compliance with §1910.333(c) and §1910.335. However, the requirements of §1910.332, §1910.333(a), §1910.333(b), and §1910.334 apply to all work on or directly associated with utilization installations, regardless of whether the work is performed by qualified or unqualified persons.
Note 3 to paragraph (c)(1): Work on or directly associated with generation, transmission, or distribution installations includes:
Note 1 to paragraph (c)(1): Work on or directly associated with installations of utilization equipment used for purposes other than generating, transmitting, or distributing electric energy (such as installations which are in office buildings, warehouses, garages, machine shops, or recreational buildings, or other utilization installations which are not an integral part of a generating installation, substation, or control center) is covered under paragraph (a)(1) of this section.
Note 2 to paragraph (c)(1): For work on or directly associated with utilization installations, an employer who complies with the work practices of §1910.269 (electric power generation, transmission, and distribution) will be deemed to be in compliance with §1910.333(c) and §1910.335. However, the requirements of §1910.332, §1910.333(a), §1910.333(b), and §1910.334 apply to all work on or directly associated with utilization installations, regardless of whether the work is performed by qualified or unqualified persons.
Note 3 to paragraph (c)(1): Work on or directly associated with generation, transmission, or distribution installations includes:
- Work performed directly on such installations, such as repairing overhead or underground distribution lines or repairing a feed-water pump for the boiler in a generating plant.
- Work directly associated with such installations, such as line-clearance tree trimming and replacing utility poles, when that work is covered by § 1910.269 (see § 1910.269(a)(1)(i)(D) and (E) and the definition of "line-clearance tree trimming" in § 1910.269(x)).
- Work on electric utilization circuits in a generating plant provided that:
- Such circuits are commingled with installations of power generation equipment or circuits, and
- The generation equipment or circuits present greater electrical hazards than those posed by the utilization equipment or circuits (such as exposure to higher voltages or lack of overcurrent protection).
Related Code Sections
1910.331(c)(1) Electrical, Generation, Transmission, and Distribution Installations
Installations for the generation, control, transformation, transmission, and distribution of electric energy (including communication and metering ...
OSHA 1910 General Industry > S Electrical > 1910.331 Scope > 1910.331(c) Excluded Work by Qualified Persons > 1910.331(c)(1) Generation, Transmission, and Distribution Installations
1910.269(a)(1)(i)(A) Special Industries,
Power generation, transmission, and distribution installations, including related equipment for the purpose of communication or metering ...
OSHA 1910 General Industry > R Special Industries > 1910.269 Electric Power Generation, Transmission, and Distribution > 1910.269(a) General > 1910.269(a)(1) Application > 1910.269(a)(1)(i) > 1910.269(a)(1)(i)(A)
1910.269(a) Special Industries, General
to: Power generation, transmission, and distribution installations, including related equipment for the purpose ...
OSHA 1910 General Industry > R Special Industries > 1910.269 Electric Power Generation, Transmission, and Distribution > 1910.269(a) General
1910.302(a)(2)(iii) Electrical,
Installations of railways for generation, transformation, transmission, or distribution of power used exclusively for operation of rolling stock ...
OSHA 1910 General Industry > S Electrical > 1910.302 Electric Utilization Systems > 1910.302(a) Scope > 1910.302(a)(2) Not Covered > 1910.302(a)(2)(iii)
1910.269(t)(4) Special Industries, Duct Rods
The employer shall ensure that, if employees use duct rods, the employees install the duct rods in the direction presenting the least hazard ...
OSHA 1910 General Industry > R Special Industries > 1910.269 Electric Power Generation, Transmission, and Distribution > 1910.269(t) Underground Electrical Installations > 1910.269(t)(4) Duct Rods