1926.353(e) General Welding, Cutting, and Heating
JUMP TO FULL CODE CHAPTER
Welding, cutting, and heating, not involving conditions or materials described in paragraph (b), (c), or (d) of this section, may normally be done without mechanical ventilation or respiratory protective equipment, but where, because of unusual physical or atmospheric conditions, an unsafe accumulation of contaminants exists, suitable mechanical ventilation or respiratory protective equipment shall be provided.
Employees performing any type of welding, cutting, or heating shall be protected by suitable eye protective equipment in accordance with the requirements of Subpart E of this part.
[44 FR 8577, Feb. 9, 1979; 44 FR 20940, Apr. 6, 1979, as amended at 55 FR 42328, Oct. 18, 1990; 58 FR 35179, June 30, 1993]
[44 FR 8577, Feb. 9, 1979; 44 FR 20940, Apr. 6, 1979, as amended at 55 FR 42328, Oct. 18, 1990; 58 FR 35179, June 30, 1993]
Related Code Sections
1926.353(e) Welding and Cutting, General Welding, Cutting, and Heating
Welding, cutting, and heating, not involving conditions or materials described in paragraph (b), (c), or (d) of this section, may normally be done ...
OSHA 1926 Construction > J Welding and Cutting > 1926.353 Ventilation and Protection in Welding, Cutting, and Heating > 1926.353(e) General Welding, Cutting, and Heating
1926.353(b) Welding and Cutting, Welding, Cutting, and Heating in Confined Spaces
meeting the requirements of paragraph (a) of this section shall be provided whenever welding, cutting, or heating is performed in a confined space ...
OSHA 1926 Construction > J Welding and Cutting > 1926.353 Ventilation and Protection in Welding, Cutting, and Heating > 1926.353(b) Welding, Cutting, and Heating in Confined Spaces
1926.353 Welding and Cutting, Ventilation and Protection in Welding, Cutting, and Heating
(a) of this section shall be provided whenever welding, cutting, or heating is performed in a confined space ...
OSHA 1926 Construction > J Welding and Cutting > 1926.353 Ventilation and Protection in Welding, Cutting, and Heating
1926.351(c) Welding and Cutting, Ground Returns and Machine Grounding
electrical contact exists at all joints. The generation of an arc, sparks, or heat at any point shall cause rejection of the structures as a ground ...
OSHA 1926 Construction > J Welding and Cutting > 1926.351 Arc Welding and Cutting > 1926.351(c) Ground Returns and Machine Grounding
1926.353(a) Welding and Cutting, Mechanical Ventilation
: Mechanical ventilation shall consist of either general mechanical ventilation systems or local exhaust ...
OSHA 1926 Construction > J Welding and Cutting > 1926.353 Ventilation and Protection in Welding, Cutting, and Heating > 1926.353(a) Mechanical Ventilation