Wheelchair spaces complying with 802.1 shall be provided in accordance with Table 221.2.1.1.
Table 221.2.1.1 Number of Wheelchair Spaces in Assembly Areas
Number of SeatsMinimum Number of Required Wheelchair Spaces
4 to 25 1
26 to 50 2
51 to 150 4
151 to 300 5
301 to 500 6
501 to 5000 6, plus 1 for each 150,
or fraction thereof, between 501 through 5000
5001 and over 36, plus 1 for each 200,
or fraction thereof, over 5000