• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1904.7 General Recording Criteria

OSHA 1904 Recordkeeping > C Recordkeeping Forms and Recording Criteria > 1904.7 General Recording Criteria
JUMP TO FULL CODE CHAPTER

1904.7(a) Basic Requirement

You must consider an injury or illness to meet the general recording criteria, and therefore to be recordable, if it results in any of the following: death, days away from work, restricted work or transfer to another job, medical treatment beyond first aid, or loss of consciousness. You must also consider a case to meet the general recording criteria if it involves a significant injury or illness diagnosed by a physician or other licensed health care professional, even if it does not result in death, days away from work, restricted work or job transfer, medical treatment beyond first aid, or loss of consciousness.

1904.7(b) Implementation

1904.7(b)(1) How Do I Decide if a Case Meets One or More of the General Recording Criteria?

A work-related injury or illness must be recorded if it results in one or more of the following:

1904.7(b)(1)(i) Death

See § 1904.7(b)(2).

1904.7(b)(1)(iii) Restricted Work or Transfer to Another Job

See § 1904.7(b)(4).

1904.7(b)(1)(iv) Medical Treatment Beyond First Aid

See § 1904.7(b)(5).

1904.7(b)(1)(v) Loss of Consciousness

See § 1904.7(b)(6).

1904.7(b)(1)(vi)

A significant injury or illness diagnosed by a physician or other licensed health care professional. See § 1904.7(b)(7).

1904.7(b)(1)(ii) Days Away From Work

See § 1904.7(b)(3).

1904.7(b)(2) How Do I Record a Work-Related Injury or Illness That Results in the Employee's Death?

You must record an injury or illness that results in death by entering a check mark on the OSHA 300 Log in the space for cases resulting in death. You must also report any work-related fatality to OSHA within eight (8) hours, as required by § 1904.39.

1904.7(b)(3) How Do I Record a Work-Related Injury or Illness That Results in Days Away From Work?

When an injury or illness involves one or more days away from work, you must record the injury or illness on the OSHA 300 Log with a check mark in the space for cases involving days away and an entry of the number of calendar days away from work in the number of days column. If the employee is out for an extended period of time, you must enter an estimate of the days that the employee will be away, and update the day count when the actual number of days is known.

1904.7(b)(3)(i) Do I Count the Day on Which the Injury Occurred or the Illness Began?

No, you begin counting days away on the day after the injury occurred or the illness began.

1904.7(b)(3)(iii) How Do I Handle a Case When a Physician or Other Licensed Health Care Professional Recommends That the Worker Return to Work but the Employee Stays at Home Anyway?

In this situation, you must end the count of days away from work on the date the physician or other licensed health care professional recommends that the employee return to work.

1904.7(b)(3)(iv) How Do I Count Weekends, Holidays, or Other Days the Employee Would Not Have Worked Anyway?

You must count the number of calendar days the employee was unable to work as a result of the injury or illness, regardless of whether or not the employee was scheduled to work on those day(s). Weekend days, holidays, vacation days or other days off are included in the total number of days recorded if the employee would not have been able to work on those days because of a work-related injury or illness.

1904.7(b)(3)(ix) If a Case Occurs in One Year but Results in Days Away During the Next Calendar Year, Do I Record the Case in Both Years?

No, you only record the injury or illness once. You must enter the number of calendar days away for the injury or illness on the OSHA 300 Log for the year in which the injury or illness occurred. If the employee is still away from work because of the injury or illness when you prepare the annual summary, estimate the total number of calendar days you expect the employee to be away from work, use this number to calculate the total for the annual summary, and then update the initial log entry later when the day count is known or reaches the 180-day cap.

1904.7(b)(3)(v) How Do I Record a Case in Which a Worker Is Injured or Becomes Ill on a Friday and Reports to Work on a Monday, and Was Not Scheduled to Work on the Weekend?

You need to record this case only if you receive information from a physician or other licensed health care professional indicating that the employee should not have worked, or should have performed only restricted work, during the weekend. If so, you must record the injury or illness as a case with days away from work or restricted work, and enter the day counts, as appropriate.

1904.7(b)(3)(vi) How Do I Record a Case in Which a Worker Is Injured or Becomes Ill on the Day Before Scheduled Time Off Such as a Holiday, a Planned Vacation, or a Temporary Plant Closing?

You need to record a case of this type only if you receive information from a physician or other licensed health care professional indicating that the employee should not have worked, or should have performed only restricted work, during the scheduled time off. If so, you must record the injury or illness as a case with days away from work or restricted work, and enter the day counts, as appropriate.

1904.7(b)(3)(vii) Is There a Limit to the Number of Days Away From Work I Must Count?

Yes, you may "cap" the total days away at 180 calendar days. You are not required to keep track of the number of calendar days away from work if the injury or illness resulted in more than 180 calendar days away from work and/or days of job transfer or restriction. In such a case, entering 180 in the total days away column will be considered adequate.

1904.7(b)(3)(viii) May I Stop Counting Days if an Employee Who Is Away From Work Because of an Injury or Illness Retires or Leaves My Company?

Yes, if the employee leaves your company for some reason unrelated to the injury or illness, such as retirement, a plant closing, or to take another job, you may stop counting days away from work or days of restriction/job transfer. If the employee leaves your company because of the injury or illness, you must estimate the total number of days away or days of restriction/job transfer and enter the day count on the 300 Log.

1904.7(b)(3)(ii) How Do I Record an Injury or Illness When a Physician or Other Licensed Health Care Professional Recommends That the Worker Stay at Home but the Employee Comes to Work Anyway?

You must record these injuries and illnesses on the OSHA 300 Log using the check box for cases with days away from work and enter the number of calendar days away recommended by the physician or other licensed health care professional. If a physician or other licensed health care professional recommends days away, you should encourage your employee to follow that recommendation. However, the days away must be recorded whether the injured or ill employee follows the physician or licensed health care professional's recommendation or not. If you receive recommendations from two or more physicians or other licensed health care professionals, you may make a decision as to which recommendation is the most authoritative, and record the case based upon that recommendation.

1904.7(b)(4) How Do I Record a Work-Related Injury or Illness That Results in Restricted Work or Job Transfer?

When an injury or illness involves restricted work or job transfer but does not involve death or days away from work, you must record the injury or illness on the OSHA 300 Log by placing a check mark in the space for job transfer or restriction and an entry of the number of restricted or transferred days in the restricted workdays column.

1904.7(b)(4)(i) How Do I Decide if the Injury or Illness Resulted in Restricted Work?

Restricted work occurs when, as the result of a work-related injury or illness:

1904.7(b)(4)(i)(A)

You keep the employee from performing one or more of the routine functions of his or her job, or from working the full workday that he or she would otherwise have been scheduled to work; or

1904.7(b)(4)(i)(B)

A physician or other licensed health care professional recommends that the employee not perform one or more of the routine functions of his or her job, or not work the full workday that he or she would otherwise have been scheduled to work.

1904.7(b)(4)(iii) Do I Have to Record Restricted Work or Job Transfer if It Applies Only to the Day on Which the Injury Occurred or the Illness Began?

No, you do not have to record restricted work or job transfers if you, or the physician or other licensed health care professional, impose the restriction or transfer only for the day on which the injury occurred or the illness began.

1904.7(b)(4)(iv) If You or a Physician or Other Licensed Health Care Professional Recommends a Work Restriction, Is the Injury or Illness Automatically Recordable as a "Restricted Work" Case?

No, a recommended work restriction is recordable only if it affects one or more of the employee's routine job functions. To determine whether this is the case, you must evaluate the restriction in light of the routine functions of the injured or ill employee's job. If the restriction from you or the physician or other licensed health care professional keeps the employee from performing one or more of his or her routine job functions, or from working the full workday the injured or ill employee would otherwise have worked, the employee's work has been restricted and you must record the case.

1904.7(b)(4)(ix) How Do I Decide if an Injury or Illness Involved a Transfer to Another Job?

If you assign an injured or ill employee to a job other than his or her regular job for part of the day, the case involves transfer to another job. Note: This does not include the day on which the injury or illness occurred.

1904.7(b)(4)(v) How Do I Record a Case Where the Worker Works Only for a Partial Work Shift Because of a Work-Related Injury or Illness?

A partial day of work is recorded as a day of job transfer or restriction for recordkeeping purposes, except for the day on which the injury occurred or the illness began.

1904.7(b)(4)(vi) If the Injured or Ill Worker Produces Fewer Goods or Services Than HE or She Would Have Produced Prior to the Injury or Illness but Otherwise Performs All of the Routine Functions of His or Her Work, Is the Case Considered a Restricted Work Case?

No, the case is considered restricted work only if the worker does not perform all of the routine functions of his or her job or does not work the full shift that he or she would otherwise have worked.

1904.7(b)(4)(vii) How Do I Handle Vague Restrictions From a Physician or Other Licensed Health Care Professional, Such as That the Employee Engage Only in "Light Duty" or "Take It Easy for a Week"?

If you are not clear about the physician or other licensed health care professional's recommendation, you may ask that person whether the employee can do all of his or her routine job functions and work all of his or her normally assigned work shift. If the answer to both of these questions is "Yes," then the case does not involve a work restriction and does not have to be recorded as such. If the answer to one or both of these questions is "No," the case involves restricted work and must be recorded as a restricted work case. If you are unable to obtain this additional information from the physician or other licensed health care professional who recommended the restriction, record the injury or illness as a case involving restricted work.

1904.7(b)(4)(viii) What Do I Do if a Physician or Other Licensed Health Care Professional Recommends a Job Restriction Meeting OSHA's Definition, but the Employee Does All of His or Her Routine Job Functions Anyway?

You must record the injury or illness on the OSHA 300 Log as a restricted work case. If a physician or other licensed health care professional recommends a job restriction, you should ensure that the employee complies with that restriction. If you receive recommendations from two or more physicians or other licensed health care professionals, you may make a decision as to which recommendation is the most authoritative, and record the case based upon that recommendation.

1904.7(b)(4)(x) Are Transfers to Another Job Recorded in the Same Way as Restricted Work Cases?

Yes, both job transfer and restricted work cases are recorded in the same box on the OSHA 300 Log. For example, if you assign, or a physician or other licensed health care professional recommends that you assign, an injured or ill worker to his or her routine job duties for part of the day and to another job for the rest of the day, the injury or illness involves a job transfer. You must record an injury or illness that involves a job transfer by placing a check in the box for job transfer.

1904.7(b)(4)(xi) How Do I Count Days of Job Transfer or Restriction?

You count days of job transfer or restriction in the same way you count days away from work, using § 1904.7(b)(3)(i) to (viii), above. The only difference is that, if you permanently assign the injured or ill employee to a job that has been modified or permanently changed in a manner that eliminates the routine functions the employee was restricted from performing, you may stop the day count when the modification or change is made permanent. You must count at least one day of restricted work or job transfer for such cases.

1904.7(b)(4)(ii) What Is Meant by "Routine Functions"?

For recordkeeping purposes, an employee's routine functions are those work activities the employee regularly performs at least once per week.

1904.7(b)(5) How Do I Record an Injury or Illness That Involves Medical Treatment Beyond First Aid?

If a work-related injury or illness results in medical treatment beyond first aid, you must record it on the OSHA 300 Log. If the injury or illness did not involve death, one or more days away from work, one or more days of restricted work, or one or more days of job transfer, you enter a check mark in the box for cases where the employee received medical treatment but remained at work and was not transferred or restricted.

1904.7(b)(5)(i) What Is the Definition of Medical Treatment?

"Medical treatment" means the management and care of a patient to combat disease or disorder. For the purposes of Part 1904, medical treatment does not include:

1904.7(b)(5)(i)(A)

Visits to a physician or other licensed health care professional solely for observation or counseling;

1904.7(b)(5)(i)(B)

The conduct of diagnostic procedures, such as x-rays and blood tests, including the administration of prescription medications used solely for diagnostic purposes (e.g., eye drops to dilate pupils); or

1904.7(b)(5)(i)(C)

"First aid" as defined in paragraph (b)(5)(ii) of this section.

1904.7(b)(5)(iii) Are Any Other Procedures Included in First Aid?

No, this is a complete list of all treatments considered first aid for Part 1904 purposes.

1904.7(b)(5)(iv) Does the Professional Status of the Person Providing the Treatment Have Any Effect on What Is Considered First Aid or Medical Treatment?

No, OSHA considers the treatments listed in § 1904.7(b)(5)(ii) of this Part to be first aid regardless of the professional status of the person providing the treatment. Even when these treatments are provided by a physician or other licensed health care professional, they are considered first aid for the purposes of Part 1904. Similarly, OSHA considers treatment beyond first aid to be medical treatment even when it is provided by someone other than a physician or other licensed health care professional.

1904.7(b)(5)(v) What if a Physician or Other Licensed Health Care Professional Recommends Medical Treatment but the Employee Does Not Follow the Recommendation?

If a physician or other licensed health care professional recommends medical treatment, you should encourage the injured or ill employee to follow that recommendation. However, you must record the case even if the injured or ill employee does not follow the physician or other licensed health care professional's recommendation.

1904.7(b)(5)(ii) What Is "First Aid"?

For the purposes of Part 1904, "first aid" means the following:

1904.7(b)(5)(ii)(A)

Using a non-prescription medication at nonprescription strength (for medications available in both prescription and non-prescription form, a recommendation by a physician or other licensed health care professional to use a non-prescription medication at prescription strength is considered medical treatment for recordkeeping purposes);

1904.7(b)(5)(ii)(B)

Administering tetanus immunizations (other immunizations, such as Hepatitis B vaccine or rabies vaccine, are considered medical treatment);

1904.7(b)(5)(ii)(C)

Cleaning, flushing or soaking wounds on the surface of the skin;

1904.7(b)(5)(ii)(D)

Using wound coverings such as bandages, Band-Aids™, gauze pads, etc.; or using butterfly bandages or Steri-Strips™ (other wound closing devices such as sutures, staples, etc., are considered medical treatment);

1904.7(b)(5)(ii)(E)

Using hot or cold therapy;

1904.7(b)(5)(ii)(F)

Using any non-rigid means of support, such as elastic bandages, wraps, non-rigid back belts, etc. (devices with rigid stays or other systems designed to immobilize parts of the body are considered medical treatment for recordkeeping purposes);
SEE MORE

Related Code Sections


1904.7 Recordkeeping Forms and Recording Criteria, General Recording Criteria
You must consider an injury or illness to meet the general recording criteria, and therefore to be recordable, if it results in any of the following ...
OSHA 1904 Recordkeeping > C Recordkeeping Forms and Recording Criteria > 1904.7 General Recording Criteria
1904.7(b)(4) Recordkeeping Forms and Recording Criteria, How Do I Record a Work-Related Injury or Illness That Results in Restricted Work or Job Transfer?
When an injury or illness involves restricted work or job transfer but does not involve death or days away from work, you must record the injury ...
OSHA 1904 Recordkeeping > C Recordkeeping Forms and Recording Criteria > 1904.7 General Recording Criteria > 1904.7(b) Implementation > 1904.7(b)(4) How Do I Record a Work-Related Injury or Illness That Results in Restricted Work or Job Transfer?
1904.7(b)(5) Recordkeeping Forms and Recording Criteria, How Do I Record an Injury or Illness That Involves Medical Treatment Beyond First Aid?
If a work-related injury or illness results in medical treatment beyond first aid, you must record it on the OSHA 300 Log. If the injury or illness ...
OSHA 1904 Recordkeeping > C Recordkeeping Forms and Recording Criteria > 1904.7 General Recording Criteria > 1904.7(b) Implementation > 1904.7(b)(5) How Do I Record an Injury or Illness That Involves Medical Treatment Beyond First Aid?
1904.7(b)(6) Recordkeeping Forms and Recording Criteria, Is Every Work-Related Injury or Illness Case Involving a Loss of Consciousness Recordable?
Yes, you must record a work-related injury or illness if the worker becomes unconscious, regardless of the length of time the employee remains ...
OSHA 1904 Recordkeeping > C Recordkeeping Forms and Recording Criteria > 1904.7 General Recording Criteria > 1904.7(b) Implementation > 1904.7(b)(6) Is Every Work-Related Injury or Illness Case Involving a Loss of Consciousness Recordable?
1904.7(b)(7) Recordkeeping Forms and Recording Criteria, What Is a "Significant" Diagnosed Injury or Illness That Is Recordable Under the General Criteria Even if It Does Not Result in Death, Days Away From Work, Restricted Work or Job Transfer, Medical Treatment Beyond First Aid, or Loss of Consciousness?
the general criteria at the time of diagnosis by a physician or other licensed health care professional. Note to § 1904.7: OSHA believes ...
OSHA 1904 Recordkeeping > C Recordkeeping Forms and Recording Criteria > 1904.7 General Recording Criteria > 1904.7(b) Implementation > 1904.7(b)(7) What Is a "Significant" Diagnosed Injury or Illness That Is Recordable Under the General Criteria Even if It Does Not Result in Death, Days Away From Work, Restricted Work or Job Transfer, Medical Treatment Beyond First Aid, or Loss of Consciousness?
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE