1010.2 Gates
JUMP TO FULL CODE CHAPTER
Gates serving the means of egress system shall comply with the requirements of this section. Gates used as a component in a means of egress shall conform to the applicable requirements for doors.
Exception: Horizontal sliding or swinging gates exceeding the 4-foot (1219 mm) maximum leaf width limitation are permitted in fences and walls surrounding a stadium.
Panic hardware is not required on gates surrounding stadiums where such gates are under constant immediate supervision while the public is present, and where safe dispersal areas based on 3 square feet (0.28 m2) per occupant are located between the fence and enclosed space. Such required safe dispersal areas shall not be located less than 50 feet (15 240 mm) from the enclosed space. See Section 1028.5 for means of egress from safe dispersal areas.
Related Code Sections
1010.2 Means of Egress, Gates
Gates serving the means of egress system shall comply with the requirements of this section. Gates used as a component in a means of egress shall ...
Building Code 2018 of Illinois > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.2 Gates
410.6 Accessible Routes, Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum. End doors ...
206.5 Scoping Requirements, Doors, Doorways, and Gates
Doors, doorways, and gates providing user passage shall be provided in accordance with 206.5 ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 206 Accessible Routes > 206.5 Doors, Doorways, and Gates
Section 3110 Special Construction, Automatic Vehicular Gates
Automatic vehicular gates shall comply with the requirements of Sections 3110.2 and 3110.3 and other applicable sections of this code ...
Section 404 Accessible Routes, Doors, Doorways, and Gates
Doors, doorways, and gates that are part of an accessible route shall comply with 404.
EXCEPTION: Doors, doorways, and gates designed ...