• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 427.2.3 Gas Cabinets

Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 427 Medical Gas Systems > 427.2 Interior Supply Location > 427.2.3 Gas Cabinets
JUMP TO FULL CODE CHAPTER

Gas cabinets shall be constructed in accordance with Section 5003.8.6 of the International Fire Code and shall comply with the following:

  1. Cabinets shall be exhausted to the exterior through a dedicated exhaust duct system installed in accordance with Chapter 5 of the International Mechanical Code.
  2. Supply and exhaust ducts shall be enclosed in a 1-hour rated shaft enclosure from the cabinet to the exterior. The average velocity of ventilation at the face of access ports or windows shall be not less than 200 feet per minute (1.02 m/s) with a minimum of 150 feet per minute (0.76 m/s) at any point of the access port or window.
  3. Cabinets shall be provided with an automatic sprinkler system internal to the cabinet.

Related Code Sections


427.2.3 Special Detailed Requirements Based on Occupancy and Use, Gas Cabinets
Gas cabinets shall be constructed in accordance with Section 5003.8.6 of the International Fire Code and shall comply with the following ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 427 Medical Gas Systems > 427.2 Interior Supply Location > 427.2.3 Gas Cabinets
415.11.7.1.3 Special Detailed Requirements Based on Occupancy and Use, Gas Cabinets, Exhausted Enclosures and Gas Rooms
A gas detection system shall be provided in gas cabinets and exhausted enclosures for HPM gas. A gas detection system shall be provided in gas ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.11 Group H-5 > 415.11.7 Gas Detection Systems > 415.11.7.1 Where Required > 415.11.7.1.3 Gas Cabinets, Exhausted Enclosures and Gas Rooms
415.11.10.1 Special Detailed Requirements Based on Occupancy and Use, Required Electrical Systems
ventilation systems . HPM gas cabinet ventilation systems . HPM exhausted enclosure ventilation systems . HPM gas room ventilation systems . HPM gas ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.11 Group H-5 > 415.11.10 Emergency Power System > 415.11.10.1 Required Electrical Systems
415.11.10 Special Detailed Requirements Based on Occupancy and Use, Emergency Power System
and connected control circuits for the following systems: HPM exhaust ventilation systems . HPM gas cabinet ventilation systems . HPM exhausted ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.11 Group H-5 > 415.11.10 Emergency Power System
Section 427 Special Detailed Requirements Based on Occupancy and Use, Medical Gas Systems
interior room or a gas cabinet in accordance with Section 427.2.1, 427.2.2 or 427.2.3, respectively. Rooms or areas where medical gases are stored or used ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 427 Medical Gas Systems
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE