• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

904.12.6.3 Fusible Link and Sprinkler Head Replacement

Fire Code 2015 of New Jersey > 9 Fire Protection Systems > 904 Alternative Automatic Fire-Extinguishing Systems > 904.12 Commercial Cooking Systems > 904.12.6 Operations and Maintenance > 904.12.6.3 Fusible Link and Sprinkler Head Replacement
JUMP TO FULL CODE CHAPTER
Fusible links and automatic sprinkler heads shall be replaced at least annually, and other protection devices shall be serviced or replaced in accordance with the manufacturer's instructions.

Exception: Frangible bulbs are not required to be replaced annually.

Related Code Sections


904.12.6.3 Fire Protection Systems, Fusible Link and Sprinkler Head Replacement
Fusible links and automatic sprinkler heads shall be replaced at least annually, and other protection devices shall be serviced or replaced ...
Fire Code 2015 of New Jersey > 9 Fire Protection Systems > 904 Alternative Automatic Fire-Extinguishing Systems > 904.12 Commercial Cooking Systems > 904.12.6 Operations and Maintenance > 904.12.6.3 Fusible Link and Sprinkler Head Replacement
910.5.1.1 Fire Protection Systems, Fusible Links
Fusible links for smoke and heat vents shall be replaced whenever fused, damaged or painted ...
Fire Code 2015 of New Jersey > 9 Fire Protection Systems > 910 Smoke and Heat Removal > 910.5 Maintenance > 910.5.1 Smoke and Heat Vents > 910.5.1.1 Fusible Links
704.2 Fire and Smoke Protection Features, Opening Protectives
fusible link type automatic door-closing devices are permitted if the fusible link rating does not exceed 135°F (57°C) ...
Fire Code 2015 of New Jersey > 7 Fire and Smoke Protection Features > 704 Floor Openings and Shafts > 704.2 Opening Protectives
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE