• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

M1305.1.1 Furnaces and Air Handlers

2014 FBC - Residential, 5th edition > 13 General Mechanical System Requirements > M1305 Appliance Access > M1305.1 Appliance Access for Inspection Service, Repair and Replacement > M1305.1.1 Furnaces and Air Handlers
JUMP TO FULL CODE CHAPTER

Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches (76 mm) along the sides, back and top with a total width of the enclosing space being at least 12 inches (305 mm) wider than the furnace or air handler. Furnaces having a firebox open to the atmosphere shall have at least a 6-inch (152 mm) working space along the front combustion chamber side. Combustion air openings at the rear or side of the compartment shall comply with the requirements of Chapter 17.

Exception: This section shall not apply to replacement appliances installed in existing compartments and alcoves where the working space clearances are in accordance with the equipment or appliance manufacturer's installation instructions.

Related Code Sections


M1305.1.1 General Mechanical System Requirements, Furnaces and Air Handlers
Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches (76 mm) along the sides, back ...
2014 FBC - Residential, 5th edition > 13 General Mechanical System Requirements > M1305 Appliance Access > M1305.1 Appliance Access for Inspection Service, Repair and Replacement > M1305.1.1 Furnaces and Air Handlers
M1305.1.1 General Mechanical System Requirements, Furnaces and Air Handlers
Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches (76 mm) along the sides, back ...
2017 FBC - Residential, 6th edition > 13 General Mechanical System Requirements > M1305 Appliance Access > M1305.1 Appliance Access for Inspection Service, Repair and Replacement > M1305.1.1 Furnaces and Air Handlers
M1305.1.1 General Mechanical System Requirements, Furnaces and Air Handlers
Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches (76 mm) along the sides, back ...
2020 FBC - Residential, 7th edition > 13 General Mechanical System Requirements > M1305 Appliance Access > M1305.1 Appliance Access for Inspection Service, Repair and Replacement > M1305.1.1 Furnaces and Air Handlers
M1305.1 General Mechanical System Requirements, Appliance Access for Inspection Service, Repair and Replacement
Furnaces and air handlers within compartments or alcoves shall have a minimum ...
2017 FBC - Residential, 6th edition > 13 General Mechanical System Requirements > M1305 Appliance Access > M1305.1 Appliance Access for Inspection Service, Repair and Replacement
R403.2.2.1 [RE] Residential Energy Efficiency, Sealed Air Handler
Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested ...
2014 FBC - Energy Conservation, 5th edition > 4 [RE] Residential Energy Efficiency > R403 Systems > R403.2 Ducts > R403.2.2 Sealing (Mandatory) > R403.2.2.1 Sealed Air Handler
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE