• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2107.2 Furnace Nameplate

NYC Fire Code 2014 > 21 Industrial Furnaces > 2107 Operation and Maintenance > 2107.2 Furnace Nameplate
JUMP TO FULL CODE CHAPTER
The following data for Class A furnaces shall be furnished on the manufacturer's nameplate:
  1. The solvent used.
  2. The number of gallons (liters) used per batch or per hour of solvent entering the furnace.
  3. The required purge time.
  4. The oven operating temperature.
  5. The exhaust blower rating for the number of gallons (liters) of solvent per hour or batch at the maximum operating temperature, or with regard to low-oxygen furnaces, the maximum allowable oxygen concentration.

Related Code Sections


Article 13 Heating and Combustion Equipment, Floor Furnaces
Floor furnaces shall be located so as to be accessible and shall not be installed in the floor of any corridor or passageway, nor in any exit ...
NYC 1968 Code (Vol I) > 14 Heating and Combustion Equipment > 13 Floor Furnaces
306.1.1 General Regulations, Central Furnaces
Central furnaces within compartments or alcoves shall have a minimum working space clearance of 3 inches (76 mm) along the sides, back and top ...
NYC Mechanical Code 2008 > 3 General Regulations > 306 Access and Service Space > 306.1 Clearances for Maintenance and Replacement > 306.1.1 Central Furnaces
306.1.1 General Regulations, Central Furnaces
Central furnaces within compartments or alcoves shall have a minimum working space clearance of 3 inches (76 mm) along the sides, back and top ...
NYC Mechanical Code 2014 > 3 General Regulations > 306 Access and Service Space > 306.1 Access for Maintenance and Replacement > 306.1.1 Central Furnaces
603.11 Duct Systems, Furnace Connections
Ducts connecting to a furnace shall have a clearance to combustibles in accordance with the furnace manufacturer's installation instructions ...
NYC Mechanical Code 2008 > 6 Duct Systems > 603 Duct Construction and Installation > 603.11 Furnace Connections
603.11 Duct Systems, Furnace Connections
Ducts connecting to a furnace shall have a clearance to combustibles in accordance with the furnace manufacturer's installation instructions ...
NYC Mechanical Code 2014 > 6 Duct Systems > 603 Duct Construction and Installation > 603.11 Furnace Connections
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE