3306.8 Full and Partial Demolition of Structural Steel, Reinforced Concrete, and Heavy Timber Construction
JUMP TO FULL CODE CHAPTER
Steel, reinforced concrete and heavy timber construction shall be demolished column length-by-column length and tier-by-tier. Any structural member that is being dismembered shall not support any load other than its own weight, and such member shall be chained or lashed in place to prevent any uncontrolled swing or drop.
Structural members shall not be thrown or dropped from the building, but shall be slowly and carefully lowered by hoists equipped with adequate brakes and non-reversing safety devices.
Related Code Sections
3306.8 Safeguards During Construction or Demolition, Full and Partial Demolition of Structural Steel, Reinforced Concrete, and Heavy Timber Construction
Steel, reinforced concrete and heavy timber construction shall be demolished column length-by-column length and tier-by-tier. Any structural member ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.8 Full and Partial Demolition of Structural Steel, Reinforced Concrete, and Heavy Timber Construction
3306.8.1 Safeguards During Construction or Demolition, Structural Steel, Reinforced Concrete, and Heavy Timber Buildings
Structural steel, reinforced concrete, and heavy timber buildings, or portions thereof, shall be demolished column length-by-column length and tier ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.8 Demolition Sequence > 3306.8.1 Structural Steel, Reinforced Concrete, and Heavy Timber Buildings
2304.10 Wood, Heavy Timber Construction
half. Frames or arches for roof construction that spring from the top of walls or wall abutments, framed timber trusses, and other roof ...
NYC Building Code 2008 > 23 Wood > 2304 General Construction Requirements > 2304.10 Heavy Timber Construction
2304.10 Wood, Heavy Timber Construction
or superimposed throughout all stories by means of reinforced concrete or metal caps with brackets, or shall be connected by properly designed steel ...
NYC Building Code 2014 > 23 Wood > 2304 General Construction Requirements > 2304.10 Heavy Timber Construction
Reference Standard 9 Loads [PDF] (page 14)
bracing 4. Braced frames where bracing carries gravity load a. Steel b. Concrete c. Heavy timber 1. Steel eccentric braced frame (EBF) 2. Light-framed ...