• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 3004 Fuel Piping

Fire Code 2021 of Colorado > 30 Industrial Ovens > 3004 Fuel Piping
JUMP TO FULL CODE CHAPTER

3004.1 Fuel-Gas Piping

Fuel-gas piping serving industrial ovens shall comply with the International Fuel Gas Code. Piping for other fuel sources shall comply with this section.

3004.2 Shutoff Valves

Each industrial oven or furnace shall be provided with an approved manual fuel shutoff valve in accordance with the International Fuel Gas Code or the International Mechanical Code.

3004.2.1 Fuel Supply Lines

Valves for fuel supply lines shall be located within 6 feet (1829 mm) of the appliance served.
Exception: Where approved and the valve is located in the same general area as the appliance served.

3004.3 Valve Position

The design of manual fuel shutoff valves shall incorporate a permanent feature that visually indicates the open or closed position of the valve. Manual fuel shutoff valves shall not be equipped with removable handles or wrenches unless the handle or wrench can only be installed parallel with the fuel line when the valve is in the open position.

Related Code Sections


Section 3004 Industrial Ovens, Fuel Piping
Fuel-gas piping serving industrial ovens shall comply with the International Fuel Gas Code . Piping for other fuel sources shall comply ...
Fire Code 2021 of Colorado > 30 Industrial Ovens > 3004 Fuel Piping
Section 3004 Industrial Ovens, Fuel Piping
Fuel-gas piping serving industrial ovens shall comply with the International Fuel Gas Code . Piping for other fuel sources shall comply ...
Fire Code 2018 of Colorado > 30 Industrial Ovens > 3004 Fuel Piping
3004.3 Industrial Ovens, Valve Position
The design of manual fuel shutoff valves shall incorporate a permanent feature that visually indicates the open or closed position of the valve ...
Fire Code 2018 of Colorado > 30 Industrial Ovens > 3004 Fuel Piping > 3004.3 Valve Position
1203.1.2 Energy Systems, Fuel Line Piping Protection
Fuel lines supplying a generator set inside a high-rise building shall be separated from areas of the building other than the room the generator ...
Fire Code 2021 of Colorado > 12 Energy Systems > 1203 Emergency and Standby Power Systems > 1203.1 General > 1203.1.2 Fuel Line Piping Protection
1203.1.2 Energy Systems, Fuel Line Piping Protection
Fuel lines supplying a generator set inside a high-rise building shall be separated from areas of the building other than the room the generator ...
Fire Code 2018 of Colorado > 12 Energy Systems > 1203 Emergency and Standby Power Systems > 1203.1 General > 1203.1.2 Fuel Line Piping Protection
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING