• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

603.1.9 Fuel Oil Transfer Maintenance

NYC Fire Code 2014 > 6 Building Services and Systems > 603 Fuel-Fired Appliances and Equipment > 603.1 Installation > 603.1.9 Fuel Oil Transfer Maintenance
JUMP TO FULL CODE CHAPTER
The fuel oil storage tanks and piping systems in which fuel oil is transferred from a stationary fuel oil storage tank installed on the lowest floor of a building to another stationary fuel oil storage tank, or to fuel-oil burning equipment, installed above such floor, shall be inspected for evidence of leaks, and stationary tank float switches shall be tested to ensure that they are in good working order, on not less than a weekly basis.

Related Code Sections


1305.3.3 Fuel-Oil Piping and Storage, Pumps
Fuel oil shall be supplied by a transfer pump or automatic pump or by other approved means ...
NYC Mechanical Code 2014 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.3 Supply Piping > 1305.3.3 Pumps
1305.3.3 Fuel-Oil Piping and Storage, Pumps
Fuel oil shall be supplied by a transfer pump or automatic pump or by other approved means ...
NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.3 Supply Piping > 1305.3.3 Pumps
1305.3.7 Fuel-Oil Piping and Storage, Piping From Transfer Pump to Equipment or Storage Tanks Above the Lowest Floor
Supply piping from a transfer pump to equipment at levels above the lowest floor or storage tanks at levels above the lowest floor in buildings shall ...
NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.3 Supply Piping > 1305.3.7 Piping From Transfer Pump to Equipment or Storage Tanks Above the Lowest Floor
Article 17 Heating and Combustion Equipment, Fuel Oil Equipment
For the purpose of this subchapter fuel oil shall mean hydrocarbon oils as classified in reference standards RS 14-3 and RS 14-12 and shall have ...
NYC 1968 Code (Vol I) > 14 Heating and Combustion Equipment > 17 Fuel Oil Equipment
1305.13 Fuel-Oil Piping and Storage, Installation of Tanks
Transfer pumps. Fuel-oil tanks shall be filled by means of a transfer pump supplied from a primary storage tank located on the lowest floor. A separate ...
NYC Mechanical Code 2014 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.13 Installation of Tanks
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE