• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

603.3 Fuel Oil Storage Systems

2010 Fire Code of NY > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.3 Fuel Oil Storage Systems
JUMP TO FULL CODE CHAPTER
Fuel oil storage systems shall be installed in accordance with this code. Fuel oil piping systems shall be installed in accordance with the Mechanical Code of New York State.

603.3.1 Maximum Outside Fuel Oil Storage Above Ground

Where connected to a fuel oil piping system, the maximum amount of fuel oil storage allowed outside above ground without additional protection shall be 660 gallons (2498 L). The storage of fuel oil above ground in quantities exceeding 660 gallons (2498 L) shall comply with NFPA 31.

603.3.2 Maximum Inside Fuel Oil Storage

Where connected to a fuel oil piping system, the maximum amount of fuel oil storage allowed inside any building shall be 660 gallons (2498 L). Where the amount of fuel oil stored inside a building exceeds 660 gallons (2498 L), the storage area shall be in compliance with the Building Code of New York State.

603.3.3 Underground Storage of Fuel Oil

The storage of fuel oil in underground storage tanks shall comply with NFPA 31.

Related Code Sections


603.3 Building Services and Systems, Fuel Oil Storage Systems
Fuel oil storage systems shall be installed in accordance with this code. Fuel-oil piping systems shall be installed in accordance ...
2020 Fire Code of NYS > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.3 Fuel Oil Storage Systems
603.3 Building Services and Systems, Fuel Oil Storage Systems
Fuel oil storage systems shall be installed in accordance with this code. Fuel oil piping systems shall be installed in accordance ...
2010 Fire Code of NY > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.3 Fuel Oil Storage Systems
603.3 Building Services and Systems, Fuel Oil Storage Systems
Fuel oil storage systems shall be installed in accordance with this code. Fuel-oil piping systems shall be installed in accordance ...
Fire Code 2015 of New York State > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.3 Fuel Oil Storage Systems
603.3.2.3 Building Services and Systems, Applicability of Maximum Allowable Quantity and Control Area Requirements
The quantity of combustible liquid stored in tanks complying with Section 603.3.2 shall not be counted towards the maximum allowable quantity set ...
2020 Fire Code of NYS > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.3 Fuel Oil Storage Systems > 603.3.2 Fuel Oil Storage Inside Buildings > 603.3.2.3 Applicability of Maximum Allowable Quantity and Control Area Requirements
603.3.2.4 Building Services and Systems, Installation
Tanks and piping systems shall be installed and separated from other uses in accordance with Section 915 and Chapter 13, both of the International ...
Fire Code 2015 of New York State > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.3 Fuel Oil Storage Systems > 603.3.2 Fuel Oil Storage Inside Buildings > 603.3.2.4 Installation
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE