• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2306.7.6 Fuel Delivery Nozzles

Fire Code 2015 of New York State > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2306 Flammable and Combustible Liquid Motor Fuel-Dispensing Facilities > 2306.7 Fuel-Dispensing Systems for Flammable or Combustible Liquids > 2306.7.6 Fuel Delivery Nozzles
JUMP TO FULL CODE CHAPTER
A listed automatic-closing-type hose nozzle valve with or without a latch-open device shall be provided on island-type dispensers used for dispensing Class I, II or III liquids.

Overhead-type dispensing units shall be provided with a listed automatic-closing-type hose nozzle valve without a latch-open device.

Exception: A listed automatic-closing-type hose nozzle valve with latch-open device is allowed to be used on overhead-type dispensing units where the design of the system is such that the hose nozzle valve will close automatically in the event the valve is released from a fill opening or upon impact with a driveway.

2306.7.6.1 Special Requirements for Nozzles

Where dispensing of Class I, II or III liquids is performed, a listed automatic-closing-type hose nozzle valve shall be used incorporating all of the following features:
  1. The hose nozzle valve shall be equipped with an integral latch-open device.
  2. Where the flow of product is normally controlled by devices or equipment other than the hose nozzle valve, the hose nozzle valve shall not be capable of being opened unless the delivery hose is pressurized. If pressure to the hose is lost, the nozzle shall close automatically.

    Exception: Vapor recovery nozzles incorporating insertion interlock devices designed to achieve shutoff on disconnect from the vehicle fill pipe.
  3. The hose nozzle shall be designed such that the nozzle is retained in the fill pipe during the filling operation.
  4. The system shall include listed equipment with a feature that causes or requires the closing of the hose nozzle valve before the product flow can be resumed or before the hose nozzle valve can be replaced in its normal position in the dispenser.

Related Code Sections


2206.7.6 Motor Fuel-Dispensing Facilities and Repair Garages, Fuel Delivery Nozzles
or equipment other than the hose nozzle valve, the hose nozzle valve shall not be capable of being opened unless the delivery hose is pressurized. If pressure ...
2010 Fire Code of NY > 22 Motor Fuel-Dispensing Facilities and Repair Garages > 2206 Flammable and Combustible Liquid Motor Fuel-Dispensing Facilities > 2206.7 Fuel-Dispensing Systems for Flammable or Combustible Liquids > 2206.7.6 Fuel Delivery Nozzles
2306.7.6 Motor Fuel-Dispensing Facilities and Repair Garages, Fuel Delivery Nozzles
by devices or equipment other than the hose nozzle valve, the hose nozzle valve shall not be capable of being opened unless the delivery hose is pressurized ...
Fire Code 2015 of New York State > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2306 Flammable and Combustible Liquid Motor Fuel-Dispensing Facilities > 2306.7 Fuel-Dispensing Systems for Flammable or Combustible Liquids > 2306.7.6 Fuel Delivery Nozzles
2306.7.6 Motor Fuel-Dispensing Facilities and Repair Garages, Fuel Delivery Nozzles
or equipment other than the hose nozzle valve, the hose nozzle valve shall not be capable of being opened unless the delivery hose is pressurized. If ...
2020 Fire Code of NYS > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2306 Flammable and Combustible Liquid Motor Fuel-Dispensing Facilities > 2306.7 Fuel-Dispensing Systems for Flammable or Combustible Liquids > 2306.7.6 Fuel Delivery Nozzles
2310.4.2 Motor Fuel-Dispensing Facilities and Repair Garages, Class II or III Liquid Fuels
with Section 5706.6. The dispensing nozzle shall be of the listed automatic-closing type without a latch-open device. Nighttime deliveries shall ...
Fire Code 2015 of New York State > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2310 Marine Motor Fuel-Dispensing Facilities > 2310.4 Fueling of Marine Vehicles at Other Than Approved Marine Motor Fuel-Dispensing Facilities > 2310.4.2 Class II or III Liquid Fuels
2310.4.2 Motor Fuel-Dispensing Facilities and Repair Garages, Class II or III Liquid Fuels
with Section 5706.6. The dispensing nozzle shall be of the listed automatic-closing type without a latch-open device. Nighttime deliveries shall only ...
2020 Fire Code of NYS > 23 Motor Fuel-Dispensing Facilities and Repair Garages > 2310 Marine Motor Fuel-Dispensing Facilities > 2310.4 Fueling of Marine Vehicles at Other Than Approved Marine Motor Fuel-Dispensing Facilities > 2310.4.2 Class II or III Liquid Fuels
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE