506.3 Frontage Increase

Building Code 2015 of Utah > 5 General Building Heights and Areas > 506 Building Area > 506.3 Frontage Increase
JUMP TO FULL CODE CHAPTER
Every building shall adjoin or have access to a public way to receive an area factor increase based on frontage. Area factor increase shall be determined in accordance with Sections 506.3.1 through 506.3.3.

506.3.1 Minimum Percentage of Perimeter

To qualify for an area factor increase based on frontage, a building shall have not less than 25 percent of its perimeter on a public way or open space. Such open space shall be either on the same lot or dedicated for public use and shall be accessed from a street or approved fire lane.

506.3.2 Minimum Frontage Distance

To qualify for an area factor increase based on frontage, the public way or open space adjacent to the building perimeter shall have a minimum distance (W) of 20 feet (6096 mm) measured at right angles from the building face to any of the following:

1. The closest interior lot line.

2. The entire width of a street, alley or public way.

3. The exterior face of an adjacent building on the same property.

Where the value of W is greater than 30 feet (9144 mm), a value of 30 feet (9144 mm) shall be used in calculating the building area increase based on frontage, regardless of the actual width of the public way or open space. Where the value of W varies along the perimeter of the building, the calculation performed in accordance with Equation 5-5 shall be based on the weighted average calculated in accordance with Equation 5-4.



where:

W (Width: weighted average) = Calculated width of public way or open space (feet).
Ln = Length of a portion of the exterior perimeter wall.
wn = Width (≥ 20 feet) of a public way or open space associated with that portion of the exterior perimeter wall.
F = Building perimeter that fronts on a public way or open space having a width of 20 feet (6096 mm) or more.


Exception: Where a building meets the requirements of Section 507, as applicable, except for compliance with the minimum 60-foot (18 288 mm) public way or yard requirement, and the value of W is greater than 30 feet (9144 mm), the value of W shall not exceed 60 feet (18 288 mm).

506.3.3 Amount of Increase

The area factor increase based on frontage shall be determined in accordance with Equation 5-5:



where:

If = Area factor increase due to frontage.
F = Building perimeter that fronts on a public way or open space having minimum distance of 20 feet (6096 mm).
P = Perimeter of entire building (feet).
W = Width of public way or open space (feet) in accordance with Section 506.3.2.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


506.3 General Building Heights and Areas, Frontage Increase
Every building shall adjoin or have access to a public way to receive an area factor increase based on frontage. Area factor increase shall ...
Building Code 2015 of Utah > 5 General Building Heights and Areas > 506 Building Area > 506.3 Frontage Increase
1401.6.2.1 Performance Compliance Methods, Allowable Area Formula
or nonsprinklered building (regardless of whether the building is sprinklered). I f = Area factor increase due to frontage as calculated ...
Existing Building Code 2015 of Utah > 14 Performance Compliance Methods > 1401 General > 1401.6 Evaluation Process > 1401.6.2 Building Area > 1401.6.2.1 Allowable Area Formula
Section 506 General Building Heights and Areas, Building Area
building (regardless of whether the building is sprinklered). I f = Area factor increase due to frontage (percent) as calculated ...
Building Code 2015 of Utah > 5 General Building Heights and Areas > 506 Building Area
506.2.4 General Building Heights and Areas, Mixed-Occupancy, Multistory Buildings
with Table 506.2 for a nonsprinklered building (regardless of whether the building is sprinklered). I f = Area factor increase due ...
Building Code 2015 of Utah > 5 General Building Heights and Areas > 506 Building Area > 506.2 Allowable Area Determination > 506.2.4 Mixed-Occupancy, Multistory Buildings
1401.6.2 Performance Compliance Methods, Building Area
f = Area factor increase due to frontage as calculated in accordance with Section 506.3 of the International Building Code ...
Existing Building Code 2015 of Utah > 14 Performance Compliance Methods > 1401 General > 1401.6 Evaluation Process > 1401.6.2 Building Area
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US