P-1106.1 Fresh Air Inlet Required
JUMP TO FULL CODE CHAPTER
All ejectors, except pneumatic ejectors or receiving tanks used for receiving
sewage or other sanitary waste, shall be provided with a fresh air inlet. The size of the fresh air inlet shall be 4 inches
for 4-inch, 5-inch, and 6-inch drain pipe and 6 inches for 8-inch drains discharging into the ejector.
Related Code Sections
P-1106.1 Vents and Venting, Fresh Air Inlet Required
inlet. The size of the fresh air inlet shall be 4 inches
for 4-inch, 5-inch, and 6-inch drain pipe and 6 inches for 8-inch drains discharging ...
Philadelphia Plumbing Code > 11 Vents and Venting > P-1106 Ejector Fresh Air Inlets and Vents > P-1106.1 Fresh Air Inlet Required
Section P-503 Traps, Cleanouts, Interceptors, and Backwater Valves, Fresh Air Inlets
Air inlets shall lead to the outer air and open at a convenient point, on the footway in the front of
the building or at the curb line, and shall ...
Philadelphia Plumbing Code > 5 Traps, Cleanouts, Interceptors, and Backwater Valves > P-503 Fresh Air Inlets
P-508.7 Traps, Cleanouts, Interceptors, and Backwater Valves, Traps
All fixture outlets shall be individually trapped, all traps shall be properly vented, and a fresh air inlet
or vent shall be installed on the house ...
Philadelphia Plumbing Code > 5 Traps, Cleanouts, Interceptors, and Backwater Valves > P-508 Interceptors and Separators > P-508.7 Traps
P-509.3 Traps, Cleanouts, Interceptors, and Backwater Valves, Vents
Every oil interceptor shall have a separate vent on the terminal end of the inlet piping and a fresh air
inlet on the sewer side of the interceptor ...
Philadelphia Plumbing Code > 5 Traps, Cleanouts, Interceptors, and Backwater Valves > P-509 Oil Interceptors > P-509.3 Vents
P-503.1 Traps, Cleanouts, Interceptors, and Backwater Valves, Location
Air inlets shall lead to the outer air and open at a convenient point, on the footway in the front of
the building or at the curb line, and shall ...
Philadelphia Plumbing Code > 5 Traps, Cleanouts, Interceptors, and Backwater Valves > P-503 Fresh Air Inlets > P-503.1 Location