• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

*§28-318.2 Frequency of Inspection

NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 318 Periodic Inspection of Gas Piping Systems > *§28-318.2 Frequency of Inspection
JUMP TO FULL CODE CHAPTER
An inspection of a building's gas piping system shall be conducted at periodic intervals as set forth by rule of the commissioner, but such inspection shall be conducted at least once every five years.

Exceptions:
  1. If the New York state public service commission adopts a rule or other requirement for periodic inspections of service lines, as defined in section 255.3 of title 16 of the New York codes, rules and regulations, with a frequency other than five years, the commissioner may, by rule, require that the periodic inspections required by this article be conducted with such frequency.
  2. The initial inspection for a new building shall be conducted in the tenth year after the earlier of (i) the issuance by the department of a letter of completion or, if applicable, a temporary or final certificate of occupancy for such building or (ii) the date such building was completed as determined by department rule.
*Section 28-318.2 was added by: Local Law 152 of 2016. This law has an effective date of December 6, 2016.

Related Code Sections


*§28-318.2 Maintenance of Buildings, Frequency of Inspection
, with a frequency other than five years, the commissioner may, by rule, require that the periodic inspections required by this article be conducted ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 318 Periodic Inspection of Gas Piping Systems > *§28-318.2 Frequency of Inspection
§28-304.5 Maintenance of Buildings, Frequency of Inspection and Testing
Elevators and other conveying systems may be subject to more frequent inspection and testing as the commissioner finds necessary to protect public ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 304 Elevators and Conveying Systems > §28-304.5 Frequency of Inspection and Testing
§28-304.5 Maintenance of Buildings, Frequency of Inspection and Testing
Elevators and other conveying systems may be subject to more frequent inspection and testing as the commissioner finds necessary to protect public ...
NYC General Admin. Provisions 2008 > 3 Maintenance of Buildings > 304 Periodic Inspection of Elevators > §28-304.5 Frequency of Inspection and Testing
§28-314.2 Maintenance of Buildings, Frequency of Inspection and Testing
The owner shall test and inspect wastewater recycling systems on a monthly basis. The commissioner may require additional testing and inspections ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 314 Periodic Wastewater Recycling System Inspection and Testing > §28-314.2 Frequency of Inspection and Testing
3310.11 Safeguards During Construction or Demolition, Modifications to the Site Safety Monitoring Program
are provided. A submission under this section may include, but not be limited to, a request to reduce or modify the type or frequency of inspections ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3310 Requirements for the Construction or Demolition of Major Buildings > 3310.11 Modifications to the Site Safety Monitoring Program
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE