// CODE SNIPPET
R324.1.3.3 Freeboard
JUMP TO FULL CODE CHAPTER
A freeboard of two feet shall be added where the design flood elevation or other elevation requirements are specified.
Exception:
A freeboard shall not be required where it is not possible to obtain a design flood elevation from the FIRM or from any method established above and the design flood elevation is three feet above the highest adjacent grade.
Related Code Sections
R324.1.3.3 Building Planning, Freeboard
A freeboard of two feet shall be added where the design flood elevation or other elevation requirements are specified.
Exception:
A freeboard ...
2010 Residential Code of NY > 3 Building Planning > R324 Flood-Resistant Construction > R324.1 General > R324.1.3 Establishing the Design Flood Elevation > R324.1.3.3 Freeboard
R324.1 Building Planning, General
building prior to construction. A freeboard of two feet ...
2010 Residential Code of NY > 3 Building Planning > R324 Flood-Resistant Construction > R324.1 General
Section R324 Building Planning, Flood-Resistant Construction
building prior to construction. A freeboard of two feet ...
R324.3 Building Planning, Coastal High-Hazard Areas (Including V Zones)
, with the exception of mat or raft foundations, piling, pile caps, columns, grade beams and bracing, is located at or above the design flood elevation plus freeboard ...
2010 Residential Code of NY > 3 Building Planning > R324 Flood-Resistant Construction > R324.3 Coastal High-Hazard Areas (Including V Zones)
Section R202 Definitions, Definitions