UpCodes logo
Go To Full Code Chapter
1926.1426(a) Boom Free Fall Prohibitions
1926.1426(a)(1)
The use of equipment in which the boom is designed to free fall (live boom) is prohibited in each of the following circumstances:
1926.1426(a)(1)(i)
An employee is in the fall zone of the boom or load.
1926.1426(a)(1)(ii)
An employee is being hoisted.
1926.1426(a)(1)(iii)
The load or boom is directly over a power line, or over any part of the area extending the Table A of § 1926.1408 clearance distance to each side of the power line; or any part of the area extending the Table A clearance distance to each side of the power line is within the radius of vertical travel of the boom or the load.
1926.1426(a)(1)(iv)
The load is over a shaft, except where there are no employees in the shaft.
1926.1426(a)(1)(v)
The load is over a cofferdam, except where there are no employees in the fall zone of the boom or the load.
1926.1426(a)(1)(vi)
Lifting operations are taking place in a refinery or tank farm.
1926.1426(a)(2)
The use of equipment in which the boom is designed to free fall (live boom) is permitted only where none of the circumstances listed in paragraph (a)(1) of this section are present and:
1926.1426(a)(2)(i)
The equipment was manufactured prior to October 31, 1984; or
1926.1426(a)(2)(ii)
The equipment is a floating crane/derrick or a land crane/derrick on a vessel/flotation device.
1926.1426(b) Preventing Boom Free Fall
Where the use of equipment with a boom that is designed to free fall (live boom) is prohibited, the boom hoist must have a secondary mechanism or device designed to prevent the boom from falling in the event the primary system used to hold or regulate the boom hoist fails, as follows:
1926.1426(b)(1)
Friction drums must have:
1926.1426(b)(1)(i)
A friction clutch and, in addition, a braking device, to allow for controlled boom lowering.
1926.1426(b)(1)(ii)
A secondary braking or locking device, which is manually or automatically engaged, to back-up the primary brake while the boom is held (such as a secondary friction brake or a ratchet and pawl device).
1926.1426(b)(2)
Hydraulic drums must have an integrally mounted holding device or internal static brake to prevent boom hoist movement in the event of hydraulic failure.
1926.1426(b)(3)
Neither clutches nor hydraulic motors must be considered brake or locking devices for purposes of this subpart.
1926.1426(b)(4)
Hydraulic boom cylinders must have an integrally mounted holding device.
1926.1426(c) Preventing Uncontrolled Retraction
Hydraulic telescoping booms must have an integrally mounted holding device to prevent the boom from retracting in the event of hydraulic failure.
1926.1426(d) Load Line Free Fall
In each of the following circumstances, controlled load lowering is required and free fall of the load line hoist is prohibited:
1926.1426(d)(1)
An employee is directly under the load.
1926.1426(d)(2)
An employee is being hoisted.
1926.1426(d)(3)
The load is directly over a power line, or over any part of the area extending the Table A of § 1926.1408 clearance distance to each side of the power line; or any part of the area extending the Table A of § 1926.1408 clearance distance to each side of the power line is within the radius of vertical travel of the load.
1926.1426(d)(4)
The load is over a shaft.
1926.1426(d)(5)
The load is over a cofferdam, except where there are no employees in the fall zone of the load.

[75 FR 48155, August 9, 2010]
Upcodes Diagrams

Related Code Sections

1926.1426(a)(1)(iii) Cranes and Derricks in Construction,
The load or boom is directly over a power line, or over any part of the area extending the Table A of § 1926.1408 clearance distance to each side ...