R502.10 Framing of Openings

Residential Code 2015 of Utah > 5 Floors > R502 WOOD FLOOR FRAMING > R502.10 Framing of Openings
JUMP TO FULL CODE CHAPTER
Openings in floor framing shall be framed with a header and trimmer joists. Where the header joist span does not exceed 4 feet (1219 mm), the header joist shall be a single member the same size as the floor joist. Single trimmer joists shall be used to carry a single header joist that is located within 3 feet (914 mm) of the trimmer joist bearing. Where the header joist span exceeds 4 feet (1219 mm), the trimmer joists and the header joist shall be doubled and of sufficient cross section to support the floor joists framing into the header.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


R502.10 Floors, Framing of Openings
Openings in floor framing shall be framed with a header and trimmer joists. Where the header joist span does not exceed 4 feet (1219 mm), the header ...
Residential Code 2015 of Utah > 5 Floors > R502 WOOD FLOOR FRAMING > R502.10 Framing of Openings
R802.9 Roof-Ceiling Construction, Framing of Openings
Openings in roof and ceiling framing shall be framed with header and trimmer joists. Where the header joist span does not exceed 4 feet (1219 mm ...
Residential Code 2015 of Utah > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.9 Framing of Openings
2304.3.2 Wood, Framing Over Openings
over window and door openings in load-bearing walls and partitions ...
Building Code 2015 of Utah > 23 Wood > 2304 General Construction Requirements > 2304.3 Wall Framing > 2304.3.2 Framing Over Openings
2308.4.4 Wood, Framing Around Openings
the performance of the conventional framing system. FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS FIGURE 2308.4.4.1(2 ...
Building Code 2015 of Utah > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing > 2308.4.4 Framing Around Openings
R804.3.5 Roof-Ceiling Construction, Framing of Openings in Roofs and Ceilings
Openings in roofs and ceilings shall be framed with header and trimmer joists. Header joist spans shall not exceed 4 feet (1219 mm) in length. Header ...
Residential Code 2015 of Utah > 8 Roof-Ceiling Construction > R804 Cold-Formed Steel Roof Framing > R804.3 Roof Construction > R804.3.5 Framing of Openings in Roofs and Ceilings
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US