Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2305.1.2.1 Framing Members

2010 Building Code of NY > 23 Wood > 2305 General Design Requirements for Lateral-Force-Resisting Systems > 2305.1 General > 2305.1.2 Framing > 2305.1.2.1 Framing Members
JUMP TO FULL CODE CHAPTER
Framing members shall be at least 2 inch (51 mm) nominal width. In general, adjoining panel edges shall bear and be attached to the framing members and butt along their centerlines. Nails shall be placed not less than 3/8 inch (9.5 mm) from the panel edge, not more than 12 inches (305 mm) apart along intermediate supports, and 6 inches (152 mm) along panel edge bearings, and shall be firmly driven into the framing members.

Related Code Sections


2305.1.2.1 Wood, Framing Members
Framing members shall be at least 2 inch (51 mm) nominal width. In general, adjoining panel edges shall bear and be attached to the framing members ...
2010 Building Code of NY > 23 Wood > 2305 General Design Requirements for Lateral-Force-Resisting Systems > 2305.1 General > 2305.1.2 Framing > 2305.1.2.1 Framing Members
(1) Wiring Methods and Materials, Framing Members
An enclosure shall be fastened to the framing members by mechanical means such as bolts, screws, or rivets, or by the use of clips or other securing ...
National Electrical Code 2017 of New York State > 3 Wiring Methods and Materials > 314 Outlet, Device, Pull, and Junction Boxes; Conduit Bodies; Fittings; And Handhole Enclosures > 314.23 Supports > (D) Suspended Ceilings > (1) Framing Members
1704.10.3.2 Structural Tests and Special Inspections, Structural Framing Members
The thickness of the sprayed fire-resistant material applied to structural members shall be determined in accordance with ASTM E 605. Thickness ...
2010 Building Code of NY > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.10 Sprayed Fire-Resistant Materials > 1704.10.3 Thickness > 1704.10.3.2 Structural Framing Members
320.17 Wiring Methods and Materials, Through or Parallel to Framing Members
Type AC cable shall be protected in accordance with 300.4(A), (C), and (D) where installed through or parallel to framing members ...
National Electrical Code 2017 of New York State > 3 Wiring Methods and Materials > 320 Armored Cable: Type AC > 320.17 Through or Parallel to Framing Members
330.17 Wiring Methods and Materials, Through or Parallel to Framing Members
Type MC cable shall be protected in accordance with 300.4(A), (C), and (D) where installed through or parallel to framing members ...
National Electrical Code 2017 of New York State > 3 Wiring Methods and Materials > 330 Metal-Clad Cable: Type MC > 330.17 Through or Parallel to Framing Members
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE