E4101.8 Frames of Ranges and Clothes Dryers
JUMP TO FULL CODE CHAPTER
Frames of
electric ranges, wall-mounted ovens, counter-mounted cooking
units, clothes dryers, and outlet or junction boxes that are
part of the circuit for these appliances shall be connected to
the equipment grounding conductor in the manner specified
in Section E3908.9. [250.140 amended]
Exception: For existing branch-circuit installations only
where an equipment grounding conductor is not present in
the outlet or junction box, the frames of electric ranges,
wall-mounted ovens, counter-mounted cooking units,
clothes dryers, and outlet or junction boxes that are part of
the circuit for these appliances may be connected to the
grounded circuit conductor if all of the following conditions
are met. [250.140 Exception]
- The supply circuit is 120/240-volt single-phase, 3- wire connected system. [250.140 Exception (1)]
- The grounded conductor is not smaller than 10 AWG copper or 8 AWG aluminum. [250.140 Exception (2)]
- The grounded conductor is insulated, or the grounded conductor is uninsulated and part of a type SE service-entrance cable and the branch circuit originates at the service equipment. [250.140 Exception (3)]
- Grounding contacts of the receptacles furnished as part of the equipment are bonded to the equipment. [250.140 Exception (4)]
Related Code Sections
E4101.8 Appliance Installation, Frames of Ranges and Clothes Dryers
Frames of
electric ranges, wall-mounted ovens, counter-mounted cooking
units, clothes dryers, and outlet or junction boxes that are
part ...
2015 Michigan Residential Code > 41 Appliance Installation > E4101 General > E4101.8 Frames of Ranges and Clothes Dryers
607.1.5 Repairs, Grounding of Appliances
Frames of electric
ranges, wall-mounted ovens, counter-mounted cooking
units, clothes dryers and outlet or junction boxes that are
part ...
2015 Michigan Rehabilitation Code > 6 Repairs > 607 Electrical > 607.1 Material > 607.1.5 Grounding of Appliances
Section 913 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Clothes Dryers
Clothes dryers shall be installed in accordance
with the manufacturer's instructions. Electric residential
clothes dryers shall be tested ...
2015 Michigan Mechanical Code > 9 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 913 Clothes Dryers
Section M1502 Exhaust Systems, Clothes Dryer Exhaust
finish or other work are
likely to penetrate the clothes dryer exhaust duct. Shield
plates shall be placed on the finished face of framing members ...
Section 504 Exhaust Systems, Clothes Dryer Exhaust
Clothes dryers shall be exhausted in accordance with the manufacturer's instructions. Dryer exhaust systems shall be independent of all other systems ...