1029.4 Foyers and Lobbies
JUMP TO FULL CODE CHAPTER
In Group A-1 occupancies, where persons are admitted to the building at times when seats are not available, such persons shall be allowed to wait in a lobby or similar space, provided that such lobby or similar space shall not encroach on the minimum width or required capacity of the means of egress. Such foyer, if not directly connected to a public street by all the main entrances or exits, shall have a straight and unobstructed corridor or path of travel to every such main entrance or exit.
Related Code Sections
1029.4 Means of Egress, Foyers and Lobbies
in a lobby or similar space, provided that such lobby or similar space shall not encroach on the minimum width or required capacity of the means ...
1030.4 Means of Egress, Foyers and Lobbies
in a lobby or similar space, provided that such lobby or similar space shall not encroach on the minimum width or required capacity of the means ...
402.1 Special Detailed Requirements Based on Occupancy and Use, Applicability
shall meet applicable provisions of this code. Exceptions: Foyers and lobbies of Groups B, R-1 and R-2 are not required to comply ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 402 Covered Mall and Open Mall Buildings > 402.1 Applicability
402.1 Special Detailed Requirements Based on Occupancy and Use, Applicability
shall meet applicable provisions of this code. Exceptions: Foyers and lobbies of Group B, R-1 and R-2 occupancies are not required to comply ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 402 Covered Mall and Open Mall Buildings > 402.1 Applicability
1020.6 Means of Egress, Corridor Continuity
on the adjacent floor leading to the exit. Exceptions: Foyers, lobbies or reception rooms constructed as required for corridors shall not be construed ...