• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1437(h)(5) Four-Year: Internal Vessel/Flotation Device Inspection

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1437 Floating Cranes/Derricks and Land Cranes/Derricks on Barges > 1926.1437(h) Inspections > 1926.1437(h)(5) Four-Year: Internal Vessel/Flotation Device Inspection
JUMP TO FULL CODE CHAPTER
For each four-year inspection:

1926.1437(h)(5)(i)

A marine engineer, marine architect, licensed surveyor, or other qualified person who has expertise with respect to vessels/flotation devices surveys the internal portion of the barge, pontoons, vessel, or other means of flotation.

1926.1437(h)(5)(ii)

If the surveyor identifies a deficiency, an immediate determination is made by the surveyor as to whether the deficiency constitutes a hazard or, though not yet a hazard, needs to be monitored in the monthly or annual inspections, as appropriate.

1926.1437(h)(5)(ii)(A)

If the surveyor determines that the deficiency constitutes a hazard, the vessel/flotation device is removed from service until it has been corrected.

1926.1437(h)(5)(ii)(B)

If the surveyor determines that, though not presently a hazard, the deficiency needs to be monitored, the deficiency is checked in the monthly or annual inspections, as appropriate.

Related Code Sections


1926.1437(h)(5) Cranes & Derricks in Construction, Four-Year: Internal Vessel/Flotation Device Inspection
, marine architect, licensed surveyor, or other qualified person who has expertise with respect to vessels/flotation devices surveys the internal ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1437 Floating Cranes/Derricks and Land Cranes/Derricks on Barges > 1926.1437(h) Inspections > 1926.1437(h)(5) Four-Year: Internal Vessel/Flotation Device Inspection
1926.1437 Cranes & Derricks in Construction, Floating Cranes/Derricks and Land Cranes/Derricks on Barges
and damage below the waterline may be determined through internal inspection of the vessel/flotation device ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1437 Floating Cranes/Derricks and Land Cranes/Derricks on Barges
1926.1437(h)(4)(i) Cranes & Derricks in Construction,
the waterline may be determined through internal inspection of the vessel/flotation device ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1437 Floating Cranes/Derricks and Land Cranes/Derricks on Barges > 1926.1437(h) Inspections > 1926.1437(h)(4) Annual: External Vessel/Flotation Device Inspection > 1926.1437(h)(4)(i)
1926.1437(h)(4) Cranes & Derricks in Construction, Annual: External Vessel/Flotation Device Inspection
be determined through internal inspection of the vessel/flotation device ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1437 Floating Cranes/Derricks and Land Cranes/Derricks on Barges > 1926.1437(h) Inspections > 1926.1437(h)(4) Annual: External Vessel/Flotation Device Inspection
1926.1437(h)(4)(i)(C) Cranes & Derricks in Construction,
of the vessel/flotation device ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1437 Floating Cranes/Derricks and Land Cranes/Derricks on Barges > 1926.1437(h) Inspections > 1926.1437(h)(4) Annual: External Vessel/Flotation Device Inspection > 1926.1437(h)(4)(i) > 1926.1437(h)(4)(i)(C)
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING