• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[BS] A406.3.1 Foundation Plan Elements

2020 Existing Building Code of NYS > A Guidelines for the Seismic Retrofit of Existing Buildings > A406 Information Required to Be on the Plans > A406.3 New Construction > A406.3.1 Foundation Plan Elements
JUMP TO FULL CODE CHAPTER
The foundation plan shall include the size, type, location and spacing of all anchor bolts with the required depth of embedment, edge and end distance; the location and size of all shear walls and all columns for braced frames or moment frames; referenced details for the connection of shear walls, braced frames or moment-resisting frames to their footing; and referenced sections for any grade beams and footings.

Related Code Sections


A406.3.1 Guidelines for the Seismic Retrofit of Existing Buildings, Foundation Plan Elements
The foundation plan shall include the size, type, location and spacing of all anchor bolts with the required depth of embedment, edge and end ...
2020 Existing Building Code of NYS > A Guidelines for the Seismic Retrofit of Existing Buildings > A406 Information Required to Be on the Plans > A406.3 New Construction > A406.3.1 Foundation Plan Elements
A406.3.1 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls, Foundation Plan Elements
The foundation plan shall include the size, type, location and spacing of all anchor bolts with the required depth of embedment, edge and end ...
Existing Building Code 2015 of New York State > A4 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls > A406 Information Required to Be on the Plans > A406.3 New Construction > A406.3.1 Foundation Plan Elements
A407.3.1 Earthquake Hazard Reduction in Existing Wood-Frame Residential Buildings With Soft, Weak or Open-Front Walls, Foundation Plan Elements
The foundation plan shall include the size, type, location and spacing of all anchor bolts with the required depth of embedment, edge and end ...
2010 Existing Building Code of NY > A4 Earthquake Hazard Reduction in Existing Wood-Frame Residential Buildings With Soft, Weak or Open-Front Walls > A407 Information Required to Be on the Plans > A407.3 New Construction > A407.3.1 Foundation Plan Elements
1810.4.3 Soils and Foundations, Location Plan
A plan showing the location and designation of deep foundation elements by an identification system shall be filed with the building official prior ...
Building Code 2015 of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.4 Installation > 1810.4.3 Location Plan
1810.4.3 Soils and Foundations, Location Plan
A plan showing the location and designation of deep foundation elements by an identification system shall be filed with the building official prior ...
2020 Building Code of New York State > 18 Soils and Foundations > 1810 Deep Foundations > 1810.4 Installation > 1810.4.3 Location Plan
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE