• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2109.5.2.5 Foundation Piers

2010 Building Code of NY > 21 Masonry > 2109 Empirical Design of Masonry > 2109.5 Thickness of Masonry > 2109.5.2 Minimum Thickness > 2109.5.2.5 Foundation Piers
JUMP TO FULL CODE CHAPTER
The minimum thickness of foundation piers shall be 8 inches (203 mm).

Related Code Sections


2109.5.2.5 Masonry, Foundation Piers
The minimum thickness of foundation piers shall be 8 inches (203 mm) ...
2010 Building Code of NY > 21 Masonry > 2109 Empirical Design of Masonry > 2109.5 Thickness of Masonry > 2109.5.2 Minimum Thickness > 2109.5.2.5 Foundation Piers
1812.1 Soils and Foundations, General
Isolated and multiple piers used as foundations shall conform to the requirements of Sections 1812.2 through 1812.10, as well as the applicable ...
2010 Building Code of NY > 18 Soils and Foundations > 1812 Pier Foundations > 1812.1 General
1812.6 Soils and Foundations, Belled Bottoms
Where pier foundations are belled at the bottom, the edge thickness of the bell shall not be less than that required for the edge of footings. Where ...
2010 Building Code of NY > 18 Soils and Foundations > 1812 Pier Foundations > 1812.6 Belled Bottoms
1812.7 Soils and Foundations, Masonry
Where the unsupported height of foundation piers exceeds six times the least dimension, the allowable working stress on piers of unit masonry shall ...
2010 Building Code of NY > 18 Soils and Foundations > 1812 Pier Foundations > 1812.7 Masonry
1812.8 Soils and Foundations, Concrete
Where adequate lateral support is not provided, and the unsupported height to least lateral dimension does not exceed three, piers of plain concrete ...
2010 Building Code of NY > 18 Soils and Foundations > 1812 Pier Foundations > 1812.8 Concrete
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE