• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3309.6 Foundation Operations Affecting Adjacent Properties

NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3309 Protection of Adjoining Property > 3309.6 Foundation Operations Affecting Adjacent Properties
JUMP TO FULL CODE CHAPTER
Whenever subsurface operations are conducted that may impose loads or movements on adjoining property, such as driving of piles, compaction of soils, or soil solidification, the effects of such operations on adjoining property and structures shall be monitored.
   Where placement of a foundation will cause changes in the ground water level under adjacent buildings, the effects of such changes on the stability and settlement of the adjacent foundations shall be investigated and provision shall be made to prevent damage to such buildings.
   When, in the opinion of the commissioner, a potential hazard exists, elevations of the adjacent buildings shall be recorded by a registered design professional at intervals of 24 hours or less as determined by the commissioner to ascertain if movement has occurred.

Related Code Sections


3309.6 Safeguards During Construction or Demolition, Foundation Operations Affecting Adjacent Properties
Whenever subsurface operations are conducted that may impose loads or movements on adjoining property, such as driving of piles, compaction of soils ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3309 Protection of Adjoining Property > 3309.6 Foundation Operations Affecting Adjacent Properties
3304.10 Safeguards During Construction or Demolition, Dewatering
be taken to prevent settlement, slope failure, and damage to adjacent buildings, structures, and property affected by dewatering operations ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3304 Soil and Foundation Work > 3304.10 Dewatering
3309.6 Safeguards During Construction or Demolition, Subsurface Operations Affecting Adjacent Properties
Whenever subsurface operations, other than excavation or fill, are conducted that may impose loads or movements on adjoining property, including ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3309 Protection of Adjoining Property > 3309.6 Subsurface Operations Affecting Adjacent Properties
§27-724 Foundations, Construction Required for or Affecting the Support of Adjacent Properties or Buildings
for or affecting the support of adjacent properties or buildings shall be subject to controlled inspection. The details of underpinning, cofferdams ...
NYC 1968 Code (Vol I) > 11 Foundations > 13 Inspection > §27-724 Construction Required for or Affecting the Support of Adjacent Properties or Buildings
1808.5.5 Soils and Foundations, Damage to Adjacent Structures or Piles
with adequate provision for the protection of adjacent buildings and property ...
NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.5 Installation > 1808.5.5 Damage to Adjacent Structures or Piles
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE