308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground.
Figure 308.2.1 Unobstructed Forward Reach
A side view is shown of a person suing a wheelchair reaching toward a wall.  The lowest vertical reach point is 15 inches (380 mm) minimum and the highest is 48 inches (1220 mm) maximum.
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction.  The high forward reach shall be 48 inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum.  Where the reach depth exceeds 20 inches (510 mm), the high forward reach shall be 44 inches (1120 mm) maximum and the reach depth shall be 25 inches (635 mm) maximum.
Figure 308.2.2 Obstructed High Forward Reach
Figure (a) shows a person seated in a wheelchair reaching a point on a wall above a protrusion, such as a wall-mounted counter, which is 20 inches (510 mm) deep maximum.  The maximum reach height is 48 inches (1220 mm).  In figure (b), the obstruction is more than 20 inches (510 mm) deep, with 25 inches (635 mm) the maximum depth.  The maximum reach height is 44 inches (1120 mm).

Related Code Sections

308.2 Building Blocks, Forward Reach
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 ...
704.4.1 Communication Elements and Features, Height
, usually the coin slot, to exceed the maximum permitted side and forward reach ranges.  (See Section 308). Advisory 704.4.1 Height Exception. While ...
1008.4.2 Recreation Facilities, Clear Floor or Ground Space
  The following table provides guidance on reach ranges for children seated in wheelchairs.  These dimensions apply to either forward or side ...
1008.4 Recreation Facilities, Play Components
seated in wheelchairs.  These dimensions apply to either forward or side reaches.  The reach ranges are appropriate for use with those play ...
704 Communication Elements and Features, Telephones
slot, to exceed the maximum permitted side and forward reach ranges.  (See Section 308). Advisory 704.4.1 Height Exception. While seats ...