• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.218 Forging Machines

OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.218 Forging Machines
JUMP TO FULL CODE CHAPTER

1910.218(a) General Requirements

1910.218(a)(1) Use of Lead

The safety requirements of this subparagraph apply to lead casts or other use of lead in the forge shop or die shop.

1910.218(a)(1)(i)

Thermostatic control of heating elements shall be provided to maintain proper melting temperature and prevent overheating.

1910.218(a)(1)(iii)

Portable units shall be used only in areas where good, general room ventilation is provided.

1910.218(a)(1)(iv)

Personal protective equipment (gloves, goggles, aprons, and other items) shall be worn.

1910.218(a)(1)(v)

A covered container shall be provided to store dross skimmings.

1910.218(a)(1)(vi)

Equipment shall be kept clean, particularly from accumulations of yellow lead oxide.

1910.218(a)(1)(ii)

Fixed or permanent lead pot installations shall be exhausted.

1910.218(a)(2)

Inspection and maintenance. It shall be the responsibility of the employer to maintain all forge shop equipment in a condition which will insure continued safe operation. This responsibility includes:

1910.218(a)(2)(i)

Establishing periodic and regular maintenance safety checks and keeping certification records of these inspections which include the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, for the forging machine which was inspected.

1910.218(a)(2)(iii)

Training personnel for the proper inspection and maintenance of forging machinery and equipment.

1910.218(a)(2)(iv)

All overhead parts shall be fastened or protected in such a manner that they will not fly off or fall in event of failure.

1910.218(a)(2)(ii)

Scheduling and recording the inspection of guards and point of operation protection devices at frequent and regular intervals. Recording of inspections shall be in the form of a certification record which includes the date the inspection was performed, the signature of the person who performed the inspection and the serial number, or other identifier, of the equipment inspected.

1910.218(a)(3) Hammers and Presses

1910.218(a)(3)(i)

All hammers shall be positioned or installed in such a manner that they remain on or are anchored to foundations sufficient to support them according to applicable engineering standards.

1910.218(a)(3)(iii)

Means shall be provided for disconnecting the power to the machine and for locking out or rendering cycling controls inoperable.

1910.218(a)(3)(iv)

The ram shall be blocked when dies are being changed or other work is being done on the hammer. Blocks or wedges shall be made of material the strength and construction of which should meet or exceed the specifications and dimensions shown in Table O-11.

TABLE O-11 - STRENGTH AND DIMENSIONS FOR WOOD RAM PROPS
Size of timber, inches 1 Square inches in cross section Minimum allowable crushing strength parallel to grain, p.s.i. 2 Maximum static load within short column range 3 Safety factor Maximum recommended weight of forging hammer for timber used Maximum allowable length of timber, inches
4 X 4 16 5,000 80,000 10 8,000 44
6 X 6 36 5,000 180,000 10 18,000 66
8 X 8 64 5,000 320,000 10 32,000 88
10 X 10 100 5,000 500,000 10 50,000 100
12 X 12 144 5,000 720,000 10 72,000 132
     Footnote(1) Actual dimension.
     Footnote(2) Adapted from U.S. Department of Agriculture Technical Bulletin 479. Hardwoods recommended are those whose ultimate crushing strengths in compression parallel to grain are 5,000 p.s.i. (pounds per square inch) or greater.
     Footnote(3) Slenderness ratio formula for short columns is L/d = 11,
where L=length of timber in inches and d=least dimension in inches;
this ratio should not exceed 11.

1910.218(a)(3)(ix)

A scale guard of substantial construction shall be provided at the back of every press, so arranged as to stop flying scale.

1910.218(a)(3)(v)

Tongs shall be of sufficient length to clear the body of the worker in case of kickback, and shall not have sharp handle ends.

1910.218(a)(3)(vi)

Oil swabs, or scale removers, or other devices to remove scale shall be provided. These devices shall be long enough to enable a man to reach the full length of the die without placing his hand or arm between the dies.

1910.218(a)(3)(vii)

Material handling equipment shall be of adequate strength, size, and dimension to handle diesetting operations safely.

1910.218(a)(3)(viii)

A scale guard of substantial construction shall be provided at the back of every hammer, so arranged as to stop flying scale.

1910.218(a)(3)(ii)

All presses shall be installed in such a manner that they remain where they are positioned or they are anchored to foundations sufficient to support them according to applicable engineering standards.

1910.218(b) Hammers, General

1910.218(b)(1) Keys

Die keys and shims shall be made from a grade of material that will not unduly crack or splinter.

1910.218(b)(2) Foot Operated Devices

All foot operated devices (i.e., treadles, pedals, bars, valves, and switches) shall be substantially and effectively protected from unintended operation.

1910.218(c) Presses

All manually operated valves and switches shall be clearly identified and readily accessible.

1910.218(d) Power-Driven Hammers

1910.218(d)(1) Safety Cylinder Head

Every steam or airhammer shall have a safety cylinder head to act as a cushion if the rod should break or pullout of the ram.

1910.218(d)(2) Shutoff Valve

Steam hammers shall be provided with a quick closing emergency valve in the admission pipeline at a convenient location. This valve shall be closed and locked in the off position while the hammer is being adjusted, repaired, or serviced, or when the dies are being changed.

1910.218(d)(3) Cylinder Draining

Steam hammers shall be provided with a means of cylinder draining, such as a self-draining arrangement or a quick-acting drain cock.

1910.218(d)(4) Pressure Pipes

Steam or air piping shall conform to the specifications of American National Standard ANSI B31.1.0-1967, Power Piping with Addenda issued before April 28, 1971, which is incorporated by reference as specified in Sec. 1910.6.

1910.218(e) Gravity Hammers

1910.218(e)(1) Air-Lift Hammers

1910.218(e)(1)(i)

Air-lift hammers shall have a safety cylinder head as required in paragraph (d)(1) of this section.

1910.218(e)(1)(iii)

Air-lift hammers shall be provided with two drain cocks: one on main head cylinder, and one on clamp cylinder.

1910.218(e)(1)(iv)

Air piping shall conform to the specifications of the ANSI B31.1.0-1967, Power Piping with Addenda issued before April 28, 1971, which is incorporated by reference as specified in Sec. 1910.6.

1910.218(e)(1)(ii)

Air-lift hammers shall have an air shutoff valve as required in paragraph (d)(2) of this section.

1910.218(e)(2) Board Drophammers

1910.218(e)(2)(i)

A suitable enclosure shall be provided to prevent damaged or detached boards from falling. The board enclosure shall be securely fastened to the hammer.

1910.218(e)(2)(ii)

All major assemblies and fittings which can loosen and fall shall be properly secured in place.

1910.218(f) Forging Presses

1910.218(f)(1) Mechanical Forging Presses

When dies are being changed or maintenance is being performed on the press, the following shall be accomplished:

1910.218(f)(1)(i) The Power to the Press Shall Be Locked Out

1910.218(f)(1)(iii)

The ram shall be blocked with a material the strength of which shall meet or exceed the specifications or dimensions shown in Table O-11.

1910.218(f)(1)(ii) The Flywheel Shall Be at Rest

1910.218(f)(2) Hydraulic Forging Presses

When dies are being changed or maintenance is being performed on the press, the following shall be accomplished:

1910.218(f)(2)(i)

The hydraulic pumps and power apparatus shall be locked out.

1910.218(f)(2)(ii)

The ram shall be blocked with a material the strength of which shall meet or exceed the specifications or dimensions shown in Table O-11.

1910.218(g) Trimming Presses

1910.218(g)(1) Hot Trimming Presses

The requirements of paragraph (f)(1) of this section shall also apply to hot trimming presses.

1910.218(g)(2) Cold Trimming Presses

Cold trimming presses shall be safeguarded in accordance with 1910.217(c).

1910.218(h) Upsetters

1910.218(h)(1) General Requirements

All upsetters shall be installed so that they remain on their supporting foundations.

1910.218(h)(2) Lockouts

Upsetters shall be provided with a means for locking out the power at its entry point to the machine and rendering its cycling controls inoperable.

1910.218(h)(3) Manually Operated Controls

All manually operated valves and switches shall be clearly identified and readily accessible.

1910.218(h)(4) Tongs

Tongs shall be of sufficient length to clear the body of the worker in case of kickback, and shall not have sharp handle ends.

1910.218(h)(5) Changing Dies

When dies are being changed, maintenance performed, or any work done on the machine, the power to the upsetter shall be locked out, and the flywheel shall be at rest.

1910.218(i) Other Forging Equipment

1910.218(i)(1) Boltheading

The provisions of paragraph (h) of this section shall apply to boltheading.

1910.218(i)(2) Rivet Making

The provisions of paragraph (h) of this section shall apply to rivet making.

1910.218(j)

Other forge facility equipment

1910.218(j)(1) Billet Shears

A positive-type lockout device for disconnecting the power to the shear shall be provided.

1910.218(j)(2) Saws

Every saw shall be provided with a guard of not less than one-eighth inch sheet metal positioned to stop flying sparks.

1910.218(j)(3) Conveyors

Conveyor power transmission equipment shall be guarded in accordance with ANSI B20.1-1957, Safety Code for Conveyors, Cableways, and Related Equipment, which is incorporated by reference as specified in Sec. 1910.6.

1910.218(j)(4) Shot Blast

The cleaning chamber shall have doors or guards to protect operators.

1910.218(j)(5) Grinding

Personal protective equipment shall be used in grinding operations, and equipment shall be used and maintained in accordance with ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of Abrasive Wheels, which is incorporated by reference as specified in Sec. 1910.6, and with 1910.215.

[39 FR 23502, June 27, 1974, as amended at 49 FR 5323, Feb. 10, 1984; 51 FR 34561, Sept. 29, 1986; 61 FR 9227, March 7, 1996]

Related Code Sections


1910.218 Machinery and Machine Guarding, Forging Machines
of the person who performed the inspection and the serial number, or other identifier, for the forging machine which was inspected ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.218 Forging Machines
1910.211(e)(7) Machinery and Machine Guarding, High-Energy-Rate Forging Machines
High-energy-rate forging machines mean a class of forging equipment wherein high ram velocities resulting from the sudden release of a compressed gas ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.211 Definitions > 1910.211(e) > 1910.211(e)(7) High-Energy-Rate Forging Machines
1910.218(d) Machinery and Machine Guarding, Power-Driven Hammers
Every steam or airhammer shall have a safety cylinder head to act as a cushion if the rod should break or pullout of the ram ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.218 Forging Machines > 1910.218(d) Power-Driven Hammers
1910.218(e) Machinery and Machine Guarding, Gravity Hammers
Air-lift hammers shall have a safety cylinder head as required in paragraph (d)(1) of this section ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.218 Forging Machines > 1910.218(e) Gravity Hammers
1910.218(g) Machinery and Machine Guarding, Trimming Presses
The requirements of paragraph (f)(1) of this section shall also apply to hot trimming presses ...
OSHA 1910 General Industry > O Machinery and Machine Guarding > 1910.218 Forging Machines > 1910.218(g) Trimming Presses
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE