3315.1.3 For Use of Workers
JUMP TO FULL CODE CHAPTER
Runways and ramps for the use of workers shall be at least 1 foot 6 inches (457 mm) in clear width. Where used for wheelbarrows, handcarts, or hand-trucks, runways and ramps shall be at least 3 feet (914 mm) in clear width. Flooring shall consist of at least 2-inch (51 mm) planking spanning as permitted by Table 3314.5.2, laid close, butt-joined and securely fastened.
Related Code Sections
3315.1.3 Safeguards During Construction or Demolition, For Use of Workers
Runways and ramps for the use of workers shall be at least 1 foot 6 inches (457 mm) in clear width. Where used for wheelbarrows, handcarts, or hand ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3315 Structural Ramps, Runways, and Platforms > 3315.1 Ramps and Runways > 3315.1.3 For Use of Workers
3315.1.3 Safeguards During Construction or Demolition, For Use of Workers
Runways and ramps for the use of workers shall be at least 1 foot 6 inches (457 mm) in clear width. Where used for wheelbarrows, handcarts, or hand ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3315 Structural Ramps, Runways and Platforms > 3315.1 Ramps and Runways > 3315.1.3 For Use of Workers
3319.10 Safeguards During Construction or Demolition, Worker Training
All workers engaged in the erection, jumping, climbing, rigging, or dismantling of a climber or tower crane, including the licensed rigger ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3319 Cranes and Derricks > 3319.10 Worker Training
3319.10 Safeguards During Construction or Demolition, Worker Training
All workers engaged in the erection, jumping, climbing, rigging, or dismantling ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3319 Cranes and Derricks > 3319.10 Worker Training
3314.15.5 Safeguards During Construction or Demolition, Number of Workers
Not more than two workers shall be permitted to work on one scaffold at one time except where the scaffold is designed to hold more. Written ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.15 Two-Point Adjustable Suspension Scaffolds > 3314.15.5 Number of Workers