• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

303A.3.4.2 For Incidental and Minor Additions, Alterations or Repairs of Pre-1973 Hospital Buildings Which Will Not Be Used for General Acute Care Services After January 1, 2030:

California Existing Building Code 2019 > 3A Provisions for All Compliance Methods > 303A Structural Design Loads and Evaluation and Design Procedures > 303A.3 Additions, Alterations, Repairs and Seismic Retrofit to Existing Buildings or Structures > 303A.3.4 Performance Objectives of Performance-Based Methods > 303A.3.4.2 For Incidental and Minor Additions, Alterations or Repairs of Pre-1973 Hospital Buildings Which Will Not Be Used for General Acute Care Services After January 1, 2030:
JUMP TO FULL CODE CHAPTER
  1. Life Safety Structural Performance (S-3) Level as defined in ASCE 41 Section 2.3.1.3 at the Basic Safety Earthquake 1E (BSE-1E) Seismic Hazard Level; and
  2. Collapse Prevention (CP) Building Performance Level (5-D) in accordance with Section 2.3.3.4 at the Basic Safety Earthquake 2E (BSE-2E) Seismic Hazard Level; and
  3. The nonstructural components shall satisfy the requirements of Position Retention Nonstructural Performance Level (N-B) in accordance with ASCE 41 Section 2.3.2.2 at BSE-1E Seismic Hazard Level.

Related Code Sections


303A.3.4.2 Provisions for All Compliance Methods, For Incidental and Minor Additions, Alterations or Repairs of Pre-1973 Hospital Buildings Which Will Not Be Used for General Acute Care Services After January 1, 2030:
; and Collapse Prevention (CP) Building Performance Level (5-D) in accordance with Section 2.3.3.4 at the Basic Safety Earthquake 2E (BSE-2E) Seismic ...
California Existing Building Code 2019 > 3A Provisions for All Compliance Methods > 303A Structural Design Loads and Evaluation and Design Procedures > 303A.3 Additions, Alterations, Repairs and Seismic Retrofit to Existing Buildings or Structures > 303A.3.4 Performance Objectives of Performance-Based Methods > 303A.3.4.2 For Incidental and Minor Additions, Alterations or Repairs of Pre-1973 Hospital Buildings Which Will Not Be Used for General Acute Care Services After January 1, 2030:
3412A.1.1 Existing Structures, ASCE 41 Section 1.4 — Performance Objectives
hospital buildings which will not be used for general acute care services after January 1, 2030: Life Safety Structural Performance (S-3) Level ...
California Building Code 2016 (Vol 1 & 2) > 34A Existing Structures > 3412A Compliance Alternatives for Additions, Alterations, Repairs and Seismic Retrofit to Existing Structures > 3412A.1 Adoption of ASCE 41 > 3412A.1.1 ASCE 41 Section 1.4 — Performance Objectives
307A.1 Provisions for All Compliance Methods, General
and supplemental services. After January 1, 2030, services/systems and utilities for acute care hospital buildings shall not originate in or pass ...
California Existing Building Code 2019 > 3A Provisions for All Compliance Methods > 307A Compliance Alternatives for Services/Systems and Utilities > 307A.1 General
3416A.1 Existing Structures, General
services. After January 1, 2030, services/systems and utilities for acute care hospital buildings shall not originate in or pass through or under ...
California Building Code 2016 (Vol 1 & 2) > 34A Existing Structures > 3416A Compliance Alternatives for Services/Systems and Utilities > 3416A.1 General
1.5.1 Seismic Evaluation Procedures for Hospital Buildings, Compliance Deadlines
with the California Administrative Code (Chapter 6), maintenance, and emergency repairs. After January 1, 2030, any general acute care hospital building ...
California Administrative Code 2019 > 6 Seismic Evaluation Procedures for Hospital Buildings > 1 Definitions and Requirements > 1.5 Compliance Requirements > 1.5.1 Compliance Deadlines
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE