2.26.1.2 For Car-Switch Operation Elevators
Go To Full Code Chapter
Handles of lever-type operating devices of car-switch operation elevators shall be arranged so that they will return to the stop position and latch there automatically when the hand of the operator is removed.
Related Code Sections
2.26.1.2 Electric Elevators, For Car-Switch Operation Elevators
Handles of lever-type operating devices of car-switch operation elevators shall be arranged so that they will return to the stop position and latch ...
2.27.3.3.2 Electric Elevators,
For elevators with power-operated doors, when the car is at a landing, with the doors open, and the "FIRE OPERATION" switch is in the "HOLD" position ...
2.12.7.3 Electric Elevators, Hoistway Access Operation
) Stopping the car at the access landing by a car leveling device while operating a hoistway access switch at the landing shall be permitted. (e) The ...
8.7.2.27.7 General Requirements, In-Car Stop Switch
On passenger elevators equipped with nonperforated car enclosures, the emergency stop switch, including all markings, shall be permitted ...
8.4.10.1.1 General Requirements, Earthquake Equipment (See Also Figure 8.4.10.1.1 and Table 8.4.10.1.1)
)], the following shall be provided in the elevator car operating panel:
(1) a Group 3 Security spring-loaded key switch labeled "EARTHQUAKE HOISTWAY ...
Safety Code for Elevators and Escalators 2019 of Illinois > 8 General Requirements > 8.4 Elevator Seismic Requirements > 8.4.10 Emergency Operation and Signaling Devices > 8.4.10.1 Operation of Elevators Under Earthquake Emergency Conditions > 8.4.10.1.1 Earthquake Equipment (See Also Figure 8.4.10.1.1 and Table 8.4.10.1.1)