418.4 Food Storage Areas
JUMP TO FULL CODE CHAPTER
Where drains are provided in storerooms, walk-in freezers, walk-in coolers, refrigerated
equipment, or other locations where food is stored, such drains shall have indirect waste piping. Separate waste pipes shall be run from each food storage area, each with an indirect connection to the building sanitary drainage system. Traps shall be provided in accordance with Section 801.3.2 of this code and shall be vented.
Indirect drains shall be permitted to be located in freezers or other spaces where freezing temperatures are maintained, provided that traps, where supplied, shall be located where the seal will not freeze. Otherwise, the floor of the freezer shall be sloped to a floor drain located outside of the storage compartment.
Indirect drains shall be permitted to be located in freezers or other spaces where freezing temperatures are maintained, provided that traps, where supplied, shall be located where the seal will not freeze. Otherwise, the floor of the freezer shall be sloped to a floor drain located outside of the storage compartment.
Related Code Sections
418.4 Plumbing Fixtures and Fixture Fittings, Food Storage Areas
, such drains shall have indirect waste piping. Separate waste pipes shall be run from each food storage area, each with an indirect connection to the building ...
California Plumbing Code 2016 > 4 Plumbing Fixtures and Fixture Fittings > 418.0 Floor Drains > 418.4 Food Storage Areas
418.4 Plumbing Fixtures and Fixture Fittings, Food Storage Areas
, such
drains shall have indirect waste piping. Separate waste pipes
shall be run from each food storage area, each with an indirect
connection to the building ...
California Plumbing Code 2019 > 4 Plumbing Fixtures and Fixture Fittings > 418.0 Floor Drains > 418.4 Food Storage Areas
310.9 General Regulations,
storage areas, and other sensitive
areas shall be kept to a minimum and shall not be
exposed. Special precautions shall be taken to protect these
areas from ...
California Plumbing Code 2016 > 3 General Regulations > 310.0 Prohibited Fittings and Practices > 310.9
310.9 General Regulations,
storage areas, and other
sensitive areas shall be kept to a minimum and shall not be
exposed. Special precautions shall be taken to protect ...
California Plumbing Code 2019 > 3 General Regulations > 310.0 Prohibited Fittings and Practices > 310.9
1224.20.2.3 Interior Environment, Storage
Food storage space shall be readily accessible to the receiving area and shall be located to exclude traffic through the food preparation area ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.20 Dietetic Service Space > 1224.20.2 Functional Elements > 1224.20.2.3 Storage