• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1309.3.7.4 Flux-Coated Brazing Rods

California Plumbing Code 2016 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.3 Brazed Joints and Fittings > 1309.3.7 Brazing Dissimilar Metals > 1309.3.7.4 Flux-Coated Brazing Rods
JUMP TO FULL CODE CHAPTER
On joints DN20 (NPS 3/4) (7/8 of an inch O.D.) size and smaller, flux-coated brazing rods shall be permitted to be used in lieu of applying flux to the surfaces being joined. [NFPA 99:5.1.10.4.4.6, 5.3.6.7.7]

Related Code Sections


1309.3.7.4 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Flux-Coated Brazing Rods
On joints DN20 (NPS 3 / 4 ) ( 7 / 8 of an inch O.D.) size and smaller, flux-coated brazing rods shall be permitted to be used in lieu of applying ...
California Plumbing Code 2016 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.3 Brazed Joints and Fittings > 1309.3.7 Brazing Dissimilar Metals > 1309.3.7.4 Flux-Coated Brazing Rods
1309.7.4 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Flux-Coated Brazing Rods
On joints DN20 (NPS 3 / 4 ) ( 7 / 8 inch O.D.) size and smaller, flux-coated brazing rods shall be permitted to be used in lieu of applying flux ...
California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.7 Brazing Dissimilar Metals > 1309.7.4 Flux-Coated Brazing Rods
1309.3.10.3 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Prohibited Brazed Joints
Joints exhibiting the following conditions shall not be permitted: Flux or flux residue (where flux or flux-coated BAg series rods are used ...
California Plumbing Code 2016 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.3 Brazed Joints and Fittings > 1309.3.10 Inspection of Brazed Joints > 1309.3.10.3 Prohibited Brazed Joints
1309.0 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Joints and Connections
] On joints DN20 (NPS 3 / 4 ) ( 7 / 8 inch O.D.) size and smaller, flux-coated brazing rods shall be permitted ...
California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections
1309.10.3 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Prohibited Brazed Joints
Joints exhibiting the following conditions shall not be permitted: Flux or flux residue (when flux or flux-coated BAg series rods are used ...
California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1309.0 Joints and Connections > 1309.10 Inspection of Brazed Joints > 1309.10.3 Prohibited Brazed Joints
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE