413.2 Flushometer Valves
Go To Full Code Chapter
Flushometer valves and flushometer tanks shall comply with ASSE 1037/ASME A112.1037/CSA B125.37, and shall be installed in accordance with Section 603.5.1. No manually controlled flushometer valve shall be used to flush more than one urinal, and each such urinal flushometer valve shall be an approved, self-closing type discharging a predetermined quantity of water. Flushometers shall be installed so that they will be accessible for repair. Flushometer valves shall not be used where the water pressure is insufficient to operate them properly. Where the valve is operated, it shall complete the cycle of operation automatically, opening fully, and closing positively under the line water pressure. Each flushometer shall be provided with a means for regulating the flow through it.
Upcodes Diagrams
Related Code Sections
413.2 Plumbing Fixtures and Fixture Fittings, Flushometer Valves
Flushometer valves and flushometer tanks shall comply with ASSE 1037/ASME A112.1037/CSA B125.37, and shall be installed in accordance with Section ...
610.10 Water Supply and Distribution, Sizing for Flushometer Valves
Where using Table 610.4 to size water supply systems serving flushometer valves, the number of flushometer fixture units assigned to every section ...
411.2.2 Plumbing Fixtures and Fixture Fittings, Flushometer Valve Activated Water Closets
Flushometer valve activated water closets shall have a maximum flush volume of 1.6 gallons (6.0 Lpf) of water per flush ...
L 402.2.2 Sustainable Practices, Flushometer-Valve Activated Water Closets
Flushometer-valve activated water closets shall have a maximum flush volume of not more than 1.28 gallons (4.8 Lpf) of water per flush in accordance ...
603.5.1 Water Supply and Distribution, Atmospheric Vacuum Breaker
Water closet and urinal flushometer valves shall be protected against backflow by an approved backflow prevention assembly, device, or method. Where ...