C402.2.5 Floors Over Outdoor Air or Unconditioned Space
JUMP TO FULL CODE CHAPTER
The minimum thermal resistance (R-value) of the insulating material installed either between the floor framing or continuously on the floor assembly shall be as specified in Table C402.2, based on construction materials used in the floor assembly.
"Mass floors" shall include floors weighing not less than:
- 35 psf (170 kg/m2) of floor surface area; or
- 25 psf (120 kg/m2) of floor surface area if the material weight is not more than 120 pcf (1,900 kg/m3).
Related Code Sections
C402.2.5 [CE] Commercial Energy Efficiency, Floors Over Outdoor Air or Unconditioned Space
The minimum thermal resistance (R-value) of the insulating material installed either between the floor framing or continuously on the floor assembly ...
Energy Conservation Code 2012 of Nevada > 4 [CE] Commercial Energy Efficiency > C402 Building Envelope Requirements > C402.2 Specific Insulation Requirements (Prescriptive) > C402.2.5 Floors Over Outdoor Air or Unconditioned Space
C402.2.3 [CE] Commercial Energy Efficiency, Floors
The thermal properties (component R-values or assembly U-, C- or F-factors) of floor assemblies over outdoor air or unconditioned space shall ...
Energy Conservation Code 2018 of Nevada > 4 [CE] Commercial Energy Efficiency > C402 Building Envelope Requirements > C402.2 Specific Building Thermal Envelope Insulation Requirements (Prescriptive) > C402.2.3 Floors
E 805.4 Sustainable Practices, Air Distribution Systems (Form MECH-4A)
by the installation or replacement of space conditioning equipment, including: replacement of the air handler; outdoor condensing unit of a split system ...
Uniform Mechanical Code 2018 of Nevada > E Sustainable Practices > E 805.0 HVAC System Tests > E 805.4 Air Distribution Systems (Form MECH-4A)
Section M1602 Duct Systems, Return Air
) from the firebox of those appliances.
An unconditioned crawl space by means of direct connection to the return side of a forced air system ...
Section M1602 Duct Systems, Return Air
where the air in such spaces is dehumidified. Taking return air from an unconditioned crawl space shall not be accomplished through a direct connection ...