// CODE SNIPPET
F102.2 Floors on Grade
Go To Full Code Chapter
Unless otherwise specified in this code, floors on grade, including but not limited to cellar floors and crawl space floors, shall be constructed of a minimum 2 inches (51 mm) thick continuous concrete slab. Gaps shall not be permitted between the slab and the abutting foundation walls or columns, except where expansion joints, thermal breaks, and control joints are located. All openings, including but not limited to, annular spaces around pipes, electric cables, and conduits in the slab shall be protected by closing such openings with cement mortar, concrete masonry, metal plates or screening designed to prevent the passage of rodents.
Related Code Sections
F102.2 Rodent-Proofing, Floors on Grade
Unless otherwise specified in this code, floors on grade, including but not limited to cellar floors and crawl space floors, shall be constructed ...
F102.2 Rodent-Proofing, Floors on Grade
Unless otherwise specified in this code, floors on grade, including but not limited to cellar floors and crawl space floors, shall be constructed ...
F102.2 Rodent Proofing, Floors on Grade
Unless otherwise specified in this code, floors on grade, including but not limited to cellar floors and crawl space floors, shall be constructed ...
§27-364 Means of Egress, Exit Discharge
space. When vertical exits serving floors above grade continue in the same enclosure to serve floors below grade, the portion of such vertical exits ...
1024.14 Means of Egress, Assembly Guards
Cross aisles located more than 30 inches (762 mm) above the floor or grade below shall have guards in accordance with Section ...