In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches (102 mm).

Related Code Sections

1209.2.1 Interior Environment, Floors and Wall Bases
intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches (102 mm) ...
1210.2.1 Interior Environment, Floors and Wall Bases
intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches (102 mm) ...
806.8 Interior Finishes, Interior Floor-Wall Base
Interior floor-wall base that is 6 inches (152 mm) or less in height shall be tested in accordance with Section 804.2 and shall be not less than ...
806.8 Interior Finishes, Interior Floor-Wall Base
Interior floor-wall base that is 6 inches (152 mm) or less in height shall be tested in accordance with Section 804.2 and shall be not less than ...
1206.2 Interior Environment, Airborne Sound
Alternatively, the sound transmission class of walls, partitions and floor-ceiling assemblies shall be established by engineering analysis based ...