• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

722.6.2.4 Floors and Roofs

2019 Oregon Structural Specialty Code (OSSC) > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.6 Wood Assemblies > 722.6.2 Walls, Floors and Roofs > 722.6.2.4 Floors and Roofs
JUMP TO FULL CODE CHAPTER
In the case of a floor or roof, the standard test provides only for testing for fire exposure from below. Except as noted in Section 703.3, Item 5, floor or roof assemblies of wood framing shall have an upper membrane consisting of a subfloor and finished floor conforming to Table 722.6.2(4) or any other membrane that has a contribution to fire resistance of not less than 15 minutes in Table 722.6.2(1).

Related Code Sections


722.6.2.4 Fire and Smoke Protection Features, Floors and Roofs
In the case of a floor or roof, the standard test provides only for testing for fire exposure from below. Except as noted in Section 703.3, Item 5 ...
2019 Oregon Structural Specialty Code (OSSC) > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.6 Wood Assemblies > 722.6.2 Walls, Floors and Roofs > 722.6.2.4 Floors and Roofs
722.6.2.4 Fire and Smoke Protection Features, Floors and Roofs
In the case of a floor or roof, the standard test provides only for testing for fire exposure from below. Except as noted in Section 703.3, Item 5 ...
2014 Oregon Structural Specialty Code (OSSC) > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.6 Wood Assemblies > 722.6.2 Walls, Floors and Roofs > 722.6.2.4 Floors and Roofs
2304.4 Wood, Floor and Roof Framing
The framing of wood-joisted floors and wood-framed roofs shall be in accordance with the provisions specified in Section 2308 unless a specific ...
2019 Oregon Structural Specialty Code (OSSC) > 23 Wood > 2304 General Construction Requirements > 2304.4 Floor and Roof Framing
2304.4 Wood, Floor and Roof Framing
The framing of wood-joisted floors and wood framed roofs shall be in accordance with the provisions specified in Section 2308 unless a specific ...
2014 Oregon Structural Specialty Code (OSSC) > 23 Wood > 2304 General Construction Requirements > 2304.4 Floor and Roof Framing
Section 711 Fire and Smoke Protection Features, Floor and Roof Assemblies
Horizontal assemblies shall comply with Section 711.2. Nonfire-resistance-rated floor and roof assemblies shall comply with Section 711.3 ...
2019 Oregon Structural Specialty Code (OSSC) > 7 Fire and Smoke Protection Features > 711 Floor and Roof Assemblies
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE