§27-557 Floor Live Loads

Go To Full Code Chapter
(a) Uniformly distributed live loads. The minimum design values established in reference standard RS 9-2 for various occupancies or uses shall be used subject to the provisions of subdivision (d) of this section. Where the occupancy or use of a space does not conform to any of those listed, the design load shall be determined by the architect or engineer subject to approval by the commissioner.

(b) Concentrated live loads.

(1) The building framing shall be capable of supporting the concentrated live loads established in reference standard RS 9-2, placed so as to produce maximum stress.

(2) Floors that support any items of machinery, electrical or mechanical equipment, or other concentrated live load in excess of one thousand pounds (including the weights of pads or bases) shall be designed to support such weight as a concentrated load or group of concentrated loads.

(c) Nonconcurrence.

(1) When a concentrated live load is present, the uniformly distributed load may be considered to be omitted in the area occupied by the concentrated load.

(2) Where reference standard RS 9-2 indicates that the concentrated live load is nonconcurrent with the uniform live load, it may be assumed that the total concentrated load is to be omitted when the uniform load is present and that the total uniform load is to be omitted when the concentrated load is present.

(d) Conformance. For purposes of determining that the magnitude of the actual live load conforms to or is less than the minimum design live load established in this section, the actual uniform live load shall be approximated by averaging the total load actually applied over a rectangular area of one hundred fifty square feet having no side less than eight feet.
Upcodes Diagrams

Related Code Sections

§27-557 Loads, Floor Live Loads
) Floors that support any items of machinery, electrical or mechanical equipment, or other concentrated live load in excess of one thousand pounds ...
§27-566 Loads, Floor Live Loads
columns, piers, and walls supporting such floor areas the maximum live load reduction shall be twenty per cent. (c) No live load reduction shall ...
1603.1.1 Structural Design, Floor Live Load
The uniformly distributed, concentrated and impact floor live load used in the design shall be indicated for floor areas. Use of live load reduction ...
1603.1.1 Structural Design, Floor Live Load
The uniformly distributed, concentrated and impact floor live load used in the design shall be indicated for floor areas. Live ...
1603.1.1 Structural Design, Floor Live Load
The uniformly distributed, concentrated and impact floor live load used in the design shall be indicated for floor areas. Live load reduction ...