• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2308.4 Floor Framing

Building Code 2021 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing
JUMP TO FULL CODE CHAPTER
Floor framing shall comply with this section.

2308.4.1 Girders

Girders for single-story construction or girders supporting loads from a single floor shall be not less than 4 inches by 6 inches (102 mm by 152 mm) for spans 6 feet (1829 mm) or less, provided that girders are spaced not more than 8 feet (2438 mm) on center. Other girders shall be designed to support the loads specified in this code. Girder end joints shall occur over supports.
Where a girder is spliced over a support, an adequate tie shall be provided. The ends of beams or girders supported on masonry or concrete shall not have less than 3 inches (76 mm) of bearing.
SEE MORE

Related Code Sections


2304.11.1.2 Wood, Floor Framing
Minimum dimensions of floor framing shall be in accordance with Table 2304.11. Approved wall plate boxes or hangers shall be provided where wood ...
Building Code 2018 of Illinois > 23 Wood > 2304 General Construction Requirements > 2304.11 Heavy Timber Construction > 2304.11.1 Details of Heavy Timber Structural Members > 2304.11.1.2 Floor Framing
2304.11.1.2 Wood, Floor Framing
Minimum dimensions of floor framing shall be in accordance with Table 2304.11. Approved wall plate boxes or hangers shall be provided where wood ...
Building Code 2021 of Illinois > 23 Wood > 2304 General Construction Requirements > 2304.11 Heavy Timber Construction > 2304.11.1 Details of Heavy Timber Structural Members > 2304.11.1.2 Floor Framing
2308.4 Wood, Floor Framing
Floor framing shall comply with this section ...
Building Code 2018 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing
2308.4 Wood, Floor Framing
Floor framing shall comply with this section ...
Building Code 2021 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing
2308.4.4.1 Wood, Openings in Floor Diaphragms in Seismic Design Categories B, C, D and E
affects the performance of the conventional framing system. FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS FIGURE 2308.4.4.1(2 ...
Building Code 2021 of Illinois > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing > 2308.4.4 Framing Around Openings > 2308.4.4.1 Openings in Floor Diaphragms in Seismic Design Categories B, C, D and E
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING