• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

33-10 Floor Area Regulations

NYC Zoning Resolution > III Commercial District Regulations > 3 - Bulk Regulations for Commercial or Community Facility Buildings in Commercial Districts > 33-10 Floor Area Regulations
JUMP TO FULL CODE CHAPTER

33-11 Definitions

Words in italics are defined in Section 12-10 or, if applicable exclusively to this Section, in this Section.

33-12 Maximum Floor Area Ratio

C1 C2 C3 C4 C5 C6 C7 C8

In all districts, as indicated, for any zoning lot, the maximum floor area ratio shall not exceed the floor area ratio set forth in this Section, except as otherwise provided in the following Sections:

Section 33-13        (Floor Area Bonus for a Public Plaza)

Section 33-14        (Floor Area Bonus for Arcades)

Section 33-15        (Floor Area Bonus for Front Yards)

Section 33-16        (Special Provisions for Zoning Lots Divided by District Boundaries)

Any given lot area shall be counted only once in determining the floor area ratio.

Where floor area in a building is shared by multiple uses, the floor area for such shared portion shall be attributed to each use proportionately, based on the percentage each use occupies of the total floor area of the zoning lot less any shared floor area.

Except where authorized by express provisions of this Resolution, the maximum floor area ratio shall not exceed the amount set forth in this Section by more than 20 percent.

In addition, the following limitations on maximum permitted floor area shall apply:

C1-8A C1-8X C1-9A C2-7A C2-7X C2-8A C4-6A C4-7A C5-1A C5-2A C6-2A C6-3A C6-3D C6-3X C6-4A

(a)        In contextual Commercial Districts

In the districts indicated, and in C1 and C2 Districts mapped within R9A, R9D, R9X, R10A or R10X Districts, no floor area bonuses are permitted.

(b)        In Community Board 7, Borough of Manhattan

Within the boundaries of Community Board 7 in Manhattan, in R10 equivalent Commercial Districts without a letter suffix, the maximum floor area ratio shall not exceed 10.0.

(c)        In C6-1A Districts

In C6-1A Districts, the maximum floor area ratio shall not exceed the amount set forth in this Section by more than 50 percent.

(d)        In C6-4X Districts

In C6-4X Districts, a floor area bonus shall only be permitted for a public plaza pursuant to Section 33-13.

33-121 In Districts With Bulk Governed by Residence District Bulk Regulations

C1-1 C1-2 C1-3 C1-4 C1-5 C2-1 C2-2 C2-3 C2-4 C2-5

In the districts indicated, for a zoning lot containing a commercial or community facility use, the maximum floor area ratio is determined by the Residence District within which such Commercial District is mapped and shall not exceed the maximum floor area ratio set forth in the following table:

MAXIMUM FLOOR AREA RATIO

District

Column A

For Zoning Lots Containing only Commercial Use

Column B

For Zoning Lots Containing only Community Facility Use

Column C

For Zoning Lots Containing both Commercial and Community Facility Uses

R1 R2

1.00

0.50

1.00

R3-1 R3A R3X

1.00

1.00

1.00

R3-2

1.00

1.60

1.60

R4 R5

1.00

2.00

2.00

R5D R6B

2.00

2.00

2.00

R6A R7B

2.00

3.00

3.00

R7A R8B

2.00

4.00*

4.00

R7D

2.00

4.20

4.20

R6 R7-1

2.00

4.80

4.80

R7X

2.00

5.00

5.00

R7-2 R8 R8A

2.00

6.50

6.50

R8X

2.00

6.00

6.00

R9

2.00

10.00

10.00

R9A

2.00

7.50

7.50

R9D

2.00

9.00

9.00

R9X

2.00

9.00

9.00

R10

2.00

10.00

10.00

________

*        In R8B Districts, within the boundaries of Community District 8 in the Borough of Manhattan, the maximum floor area ratio on a zoning lot containing community facility use exclusively shall not exceed 5.10

In addition, the following provisions shall apply:

(a)        For zoning lots containing both commercial uses and community facility uses, the total floor area used for commercial uses shall not exceed the amount permitted for zoning lots containing only commercial uses set forth in Column A.

(b)        In C1 and C2 Districts mapped within R1 and R2 Districts, the maximum floor area ratio for community facility uses on a zoning lot containing both commercial uses and community facility uses is 0.50 unless it is increased pursuant to the special permit provisions of Section 74-902 (Certain community facility uses in R1 and R2 Districts and certain Commercial Districts.)

(c)        In C1 and C2 Districts mapped within R1, R2, R3-1, R3A and R3X Districts in the Borough of Staten Island and in Community District 10 in the Borough of the Bronx, the maximum floor area ratio for any zoning lot containing a building used for ambulatory diagnostic or treatment health care facilities, as listed in Section 22-14 (Use Group 4), or child care services, as listed under the definition of school in Section 12-10 (DEFINITIONS) shall be 1.2.

(d)        In C1 and C2 Districts mapped within R3, R4, R5, R6, R7, R8 and R9 Districts, for any zoning lot containing philanthropic or non-profit institutions with sleeping accommodations, or in C1 and C2 Districts mapped within R3-1, R3A, R3X, R4-1, R4A, R4B, R5A, R5B and R5D Districts, for any zoning lot containing long-term care facilities, the total floor area for all such community facility uses shall not exceed the amount as set forth in paragraph (b) of Section 24-111 (Maximum floor area ratio for certain community facility uses) or, for Quality Housing buildings, as set forth in Section 23-153, unless modified pursuant to Section 74-903.

(e)        The maximum floor area ratio for any zoning lot used partly for commercial uses and partly for long-term care facilities in C1 and C2 Districts mapped within R3-1, R3A, R3X, R4-1, R4A, R4B, R5A, R5B and R5D Districts, or philanthropic or non-profit institutions with sleeping accommodations in C1 or C2 Districts mapped within R3 through R9 Districts, shall not exceed the amount permitted for a zoning lot containing commercial uses as set forth for the applicable Residence District within which such Commercial District is mapped in Column A. However, for the districts in which the allowable floor area ratio, as set forth in paragraph (b) of Section 24-111 or, for Quality Housing buildings, as set forth in Section 23-153, exceeds the amount permitted for a zoning lot containing commercial uses, as set forth in Column A, the provisions of paragraph (b) of Section 24-111 or Section 23-153, as applicable, shall be used to compute the maximum floor area permissible for the zoning lot unless modified pursuant to Section 74-903.

33-122 Commercial Buildings in All Other Commercial Districts

C1-6 C1-7 C1-8 C1-9 C2-6 C2-7 C2-8 C3 C4 C5 C6 C7 C8

In the districts indicated, the maximum floor area ratio for a zoning lot containing only commercial uses shall not exceed the floor area ratio set forth in the following table:

Districts

Maximum Floor Area Ratio

C3

0.50

C4-1 C8-1

1.00

C1-6 C1-7 C1-8 C1-9 C2-6 C2-7 C2-8 C7 C8-2 C8-3

2.00

C4-2A C4-3A

3.00

C4-2 C4-2F C4-3 C4-4 C4-4D C4-5 C4-6

3.40

C4-4A C4-4L C4-5A C4-5X C5-1

4.00

C4-5D

4.20

C8-4

5.00

C6-1 C6-2 C6-3

6.00

C6-3D

9.00

C4-7 C5-2 C5-4 C6-4 C6-5 C6-8

10.00

C5-3 C5-5 C6-6 C6-7 C6-9

15.00

33-123 Community Facility Buildings or Buildings Used for Both Community Facility and Commercial Uses in All Other Commercial Districts

C1-6 C1-7 C1-8 C1-9 C2-6 C2-7 C2-8 C3 C4 C5 C6 C8

In the districts indicated, the maximum floor area ratio for a zoning lot containing community facility uses, or for a zoning lot containing both commercial and community facility uses, shall not exceed the floor area ratio set forth in the following table:

Districts

Maximum Floor Area Ratio

C3

1.00

C4-1

2.00

C8-1

2.40

C4-2A C4-3A

3.00

C1-6A C2-6A C4-4A C4-4L C4-5A

4.00

C4-5D

4.20

C4-2 C4-3 C8-2

4.80

C4-5X

5.00

C6-1A

6.00

C1-6 C1-7 C2-6 C4-2F C4-4 C4-4D C4-5 C6-1 C6-2 C8-3 C8-4

6.50

C1-8A C2-7A C6-3A

7.50

C1-8X C2-7X C6-3D C6-3X

9.00

C1-8 C1-9 C2-7 C2-8 C4-6 C4-7 C5-1 C5-2 C5-4 C6-3 C6-4 C6-5 C6-8

10.00

C5-3 C5-5 C6-6 C6-7 C6-9

15.00

For zoning lots containing both commercial uses and community facility uses, the total floor area used for commercial uses shall not exceed the amount permitted for zoning lots containing only commercial uses in Section 33-122.

In addition, the following provisions shall apply:

(a)        In all Commercial Districts except C8 Districts, or districts with a residential equivalent of an R10 District, for any zoning lot containing philanthropic or non-profit institutions with sleeping accommodations, the total floor area used for such community facility use shall not exceed the amount as set forth in paragraph (b) of Section 24-111 (Maximum floor area ratio for certain community facility uses) or, for Quality Housing buildings, as set forth in Section 23-153, applying the equivalent Residence District (indicated in Section 34-112) for the Commercial District in which such use is located, unless modified pursuant to Section 74-903 (Certain community facility uses in R3 to R9 Districts and certain Commercial Districts).

(b)        The maximum floor area ratio for any zoning lot used partly for commercial use and partly for philanthropic or non-profit institutions with sleeping accommodations in Commercial Districts other than C8 Districts, or Commercial Districts with a residential equivalent of an R10 District, shall not exceed the amount permitted for a zoning lot containing commercial uses by the applicable district regulations. However, for the districts in which the allowable floor area ratio, as set forth in paragraph (b) of Section 24-111 or, for Quality Housing buildings, as set forth in Section 23-153, exceeds the amount permitted for a zoning lot containing commercial uses, the provisions of paragraph (b) of Section 24-111 or Section 23-153, as applicable, shall be used to compute the maximum floor area permissible for the zoning lot unless modified pursuant to Section 74-903.

33-124 Existing Public Amenities for Which Floor Area Bonuses Have Been Received

(a)        Elimination or reduction in size of non-bonused open area on a zoning lot containing a bonused amenity

In all districts, any existing open area for which a floor area bonus has not been utilized that occupies the same zoning lot as an existing publicly accessible open area or other public amenity, open or enclosed, for which a floor area bonus has been utilized, may be reduced in size or eliminated only upon certification of the Chairperson of the City Planning Commission that all bonused amenities comply with the standards under which such floor area bonus was granted.

(b)        Kiosks and open air cafes

Kiosks and open air cafes may be placed within an existing publicly accessible open area for which a floor area bonus has been received by certification, pursuant to Section 37-73 (Kiosks and Open Air Cafes).

(c)        Nighttime closing of existing public open areas

In all Commercial Districts, the City Planning Commission may, upon application, authorize the closing during certain nighttime hours of an existing publicly accessible open area for which a floor area bonus has been received, pursuant to Section 37-727 (Hours of access).

(d)        Elimination or reduction in size of existing public amenities

In all Commercial Districts, no existing publicly accessible open area or other public amenity, open or enclosed, for which a floor area bonus has been utilized, shall be eliminated or reduced in size, except by special permit of the City Planning Commission, pursuant to Section 74-761 (Elimination or reduction in size of bonused public amenities).

SEE MORE

Related Code Sections


505.1 General Building Heights and Areas; Separation of Occupancies, General
to either the building area or number of stories as regulated by Section 503.1. The area of the mezzanine shall be included in determining the fire area ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 505 Mezzanines > 505.1 General
505.1 General Building Heights and Areas; Separation of Occupancies, General
not contribute to either the building area or number of stories as regulated by Section 503.1. The area of the mezzanine shall be included ...
NYC Building Code 2014 > 5 General Building Heights and Areas; Separation of Occupancies > 505 Mezzanines and Equipment Platforms > 505.1 General
305.10 General Regulations, Repair Garages
Appliances installed in repair garages shall be installed in a detached building or room, separated from repair areas by walls or partitions, floors ...
NYC Fuel Gas Code 2014 > 3 General Regulations > 305 Installation > 305.10 Repair Garages
305.4 General Regulations, Public Garages, Motor Fuel-Dispensing Facilities and Repair Garages
with Section 305.3 and NFPA 88B.   2. Appliances installed in repair garages shall be separated from repair areas by walls or partitions, floors ...
NYC Fuel Gas Code 2008 > 3 General Regulations > 305 Installation > 305.4 Public Garages, Motor Fuel-Dispensing Facilities and Repair Garages
§27-822 Heating and Combustion Equipment, Pressure Regulator
In gas-fired furnaces, a gas pressure regulator shall be provided so that the gas input does not exceed the manufacturer's rating. Pressure ...
NYC 1968 Code (Vol I) > 14 Heating and Combustion Equipment > 13 Floor Furnaces > §27-822 Pressure Regulator
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE